SC390: TD sensor error
-Definition- [B]
The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively
during copying.
- Possible causes -
· TD sensor abnormal
· Poor connection of the PCU
If I could be of further assistance, let me know. If this helps or solves the issue, please rate it and give a testimonial for my response
Thanks, Joe
I’m happy to assist further over the phone at https://www.6ya.com/expert/joe_8b8c2cd6ce148309
- Possible causes -
· TD sensor abnormal
· Poor connection of the PCU
1,848 views
Usually answered in minutes!
I have a problem with sc390
Would you please give me more information on the problem. Does the display show any error code?
Thanks. Keep me posted
After 8 -10 copies, my ricoh 2020 display Sc390. please what is the solution?
×