Zero-crossing signal problem • The main PCB does not detect the zero-crossing signal (Z CROSS SIG) for the time specified below. Causes Poor contact in the connector terminals. - Check the connection of connectors YC1-3 on the main PCB and YC2-6 on the power source PCB, and the continuity across the connector terminals. Repair or replace if necessary. Defective power source PCB. - Check if the zero-crossing signal is output from YC2-6 on the power source PCB. If not, replace the power source PCB. Defective main PCB. - Replace the main PCB if C6400 is detected while YC2-6 on the power source PCB outputs the zero-crossing signal.