SOURCE: my sony k530i connect to pc for gdfs backup it
Hi,
Follow the steps mentioned below to take a backup:
1. Download latest version of xs++ software on your pc and install it.
2.Switch off the phone and remove the battery and reinsert it once again.
3. Click on connect and then Connect the USB cable to your PC while holding down the "C" button.
4. In configuration tab choose GDFS tab.
5. Click Backup GDFS.
If you still have a problem then GDFS is damaged so your phone will not work properly.
Hope this helps.
Please feel free to contact if you have any queries.
Shane
E5 indicates excessive temp. of the outside coil if on cooling, OR excessive temp of the inside coil in
heat mode. On cooling, the E5 will appear if the outside coil temp exceeds 68C. This is an indication
of condenser airflow reduced or non-existent. Using the procedure described above it is possible to
watch the condenser coil temp using the Temp down button and Medium fan speed combination to
display this temp. NB: if fans etc seem to be OK then measure thermistor resistance and refer to table
12. In case the problem is thermistor calibration.
Action: If unit is in cooling mode, examine both condenser fans are running. If
one is running then suspect a faulty motor. If both fans not running then
on units up to serial No. IBSA 01175, investigate the fan speed control
card located in enclosure on the LHS See fig 6.
If this checks OK then investigate main control card.
Fig 1, 2 or 3. Units with serial No's IBSA01176 and
onward are multi speed tapped wound motors not requiring a speed
control card. If both motors inoperative then suspect main control card
184 views