F5
- E1 Self clean latch will not
lock
1.
If door latched:
switch to control. If no damage to wires and all connectors okay, proceed to
step C.
memory. F2 will appear. Press CANCEL and observe for 1 minute to ensure
operation is correct.
2. If door not latched:
switch to control. If no damage to wires and all connectors okay, proceed to
step C.
3. Measure door switch (door open = switch open small low voltage terminals).
Replace switch if defective.
4. Measure latch switch (unlatch = switch open,
CAUTION - oven light contacts are closed). Replace switch if defective.
5. If
corrections are made in any step, reconnect power to control. Press and hold any
key for 1 minute to clear R failure code from memory. F2 will appear. Press
CANCEL and observe for 1 minute to ensure operation is correct.
6. If failure
remains, disconnect power and replace control.