Hello Dear ,
Pls do as i define to you.
This will come due to secondery transfer eng mechanism
It may be due to sec transfer engagement sensor replace/clean them.
May be secondery transfer eng solenoid replace them
May be feed motor will be faulty
May be DC controller card faulty
First check step by step it may be solve in first two steps.
59.99 An error occurred in the secondary transfer engaging
mechanism. following four possibilities are mention below with proposed action:-
1. Faulty secondary transfer engagement sensor. Replace the
secondary transfer engagement sensor.
2. Faulty secondary transfer engaging solenoid. Replace the
secondary transfer engaging solenoid.
3. Faulty feed motor. Replace the feed motor.
4. Faulty DC controller PCB Action: Replace the DC
controller PCB.
Good Luck
do Rate if got gelp
1,490 views