HP Photosmart 475 InkJet Printer Logo

Related Topics:

Posted on May 09, 2008
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Power loss loss of during shutdown. could not switch back on.

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

  • Master 3,587 Answers
  • Posted on May 09, 2008
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

Joined: Feb 02, 2008
Answers
3587
Questions
29
Helped
1146978
Points
9064

Hmmm..check the power supply cord being installed correctly, eh?

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2helpful
2answers

Error light in my apc smart ups sc 1500va ups

1. Four beeps every 30seconds (On Battery LED will be illuminated)
This alarm indicates that the Battery PowerSupplied outlets are now supplying battery power as opposed to power from theutility. If the UPS determines that the input utility power is unsafe for yourcomputer equipment, the UPS will switch to battery power.
Note: Ifthe power disturbance is brief, you may only hear one or two beeps.

2. Continuous Beeping (On Battery LED will beilluminated)
This alarm indicates that a Low Batterycondition has been reached and that the UPS will soon shutdown. Once the UPStransfers to On Battery operation, it can only stay on battery for a limitedamount of time. The UPS will sound this alarm about two minutes before thebatteries are totally exhausted. Once exhausted, the UPS will shutdown and turnoff its output power to your equipment. If you hear this tone you shouldimmediately shutdown your computer to prevent data loss or corruption.

3. Continuous Beeps for 30 seconds (BackUPS OFFICE 250 and 280 ONLY)
This alarm indicates the unit has detected anOverload condition after it has performed a self-test during start-up.

4. Continuous Two-Tone Beep
This alarm indicates a severe Overload wasdetected while the unit was on-battery operation. This tone will continue tosound until the unit shuts down.

5. Continuous Tone (On Battery LED will beflashing)
This alarm indicates that the battery-poweredoutlets are overloaded.

6. Continuous Tone (On Line and On BatteryLEDs flashing) Back UPS OFFICE 350,400, and 500 ONLY
This alarm indicates that an internal UPS faulthas occurred.
0helpful
1answer

Screen goes black but audio still works fine.

It sounds like the vertical output IC may have some solder issues. Often bad solder in the vertical circuit will cause the CRT'S ( Picture tubes) to shutdown for protection during loss of deflection and audio will continue to function. I would inspect the solder on the Vertical IC first.
0helpful
1answer

On start, I get a "No bootable device--insert boot disk and press any key" message

This means that the Boot sequence part of Windows has becoming corrupted. If the FIXBOOT boot command does not work for you during the repair option, when inserting your system discs, then you have no alternative than to reinstall Windows.

If there is data on the drive that you need, then I would advise getting a USB to hard drive adapter and transfering the files to another PC before reformating.

This fault usually occurs during incorrect shutdowns,, hard resets, or power loss whilst the computer is switched on.
6helpful
1answer

Strange noise comes out from the ups after a power cut

The Back-UPS Office unit has five different tones or alarms:

1. Four beeps every 30 seconds (On Battery LED will be illuminated)
This alarm indicates that the Battery Power Supplied outlets are now supplying battery power as opposed to power from the utility. If the UPS determines that the input utility power is unsafe for your computer equipment, the UPS will switch to battery power.
Note: If the power disturbance is brief, you may only hear one or two beeps.

2. Continuous Beeping (On Battery LED will be illuminated)
This alarm indicates that a Low Battery condition has been reached and that the UPS will soon shutdown. Once the UPS transfers to On Battery operation, it can only stay on battery for a limited amount of time. The UPS will sound this alarm about two minutes before the batteries are totally exhausted. Once exhausted, the UPS will shutdown and turn off its output power to your equipment. If you hear this tone you should immediately shutdown your computer to prevent data loss or corruption.

3. Continuous Beeps for 30 seconds (Back UPS OFFICE 250 and 280 ONLY)
This alarm indicates the unit has detected an Overload condition after it has performed a self-test during start-up.

4. Continuous Two-Tone Beep
This alarm indicates a severe Overload was detected while the unit was on-battery operation. This tone will continue to sound until the unit shuts down.

5. Continuous Tone (On Battery LED will be flashing)
This alarm indicates that the battery-powered outlets are overloaded.

6. Continuous Tone (On Line and On Battery LEDs flashing) Back UPS OFFICE 350, 400, and 500 ONLY
This alarm indicates that an internal UPS fault has occurred.
0helpful
1answer

Abrupt loss of picture during DIRECTV-source

Ur main video backllight board it dying,must be replaced.
1helpful
1answer

Netbook 2oo 70%battery power loss wheb switched

Toshiba has many ways to log off, you need to make sure that you click start and click on the right arrow and then shutdown, as it sound that your computer go to hibernation or sleep mode and not totally off.…Hope that help you and please do not forget to rate my service to be able to improve on it and help everyone
0helpful
1answer

Loss of power

First thing I would check is your regulator, a small rectangular box, that regulates electrics.
0helpful
1answer

Tv Powers up and immediately back off

This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source) 1. Shutdown at power with self diagnosis error 2-2. Check for open fuses F9A04 and F9A05 part # 283P144080 on the +24 and -24 volt lines. If the fuses are open the convergence output circuit would be suspect. 2. Shutdown at power with self diagnosis error 2-1. At power on check for 12-volts DC at connector KH pin 8, if missing check IC9C51 part # 270P990010 and L9C52 part # 441D009020 on the Signal PCB
0helpful
1answer

What do you look for when the tv want stay on?

This model is equipped with a self-diagnosis feature to help with diagnosis of shutdown problems. To activate this turn the unit on let it shutdown then press the input and menu buttons on the front panel simultaneously and hold them in for 5 seconds after 5 seconds the power LED on the front panel will blink a two digit sequence. This will be one set of blinks a short pause then another set of blinks, this will repeat 5 times. 1 - 2 = no error detected 2 - 1 = X-ray protect (high voltage or beam current) 2 - 2 = Short protect (short protect monitors low voltage supplies) 2 - 3 = Deflection protect (this could be loss of vertical or horizontal deflection) 2 - 4 = Vertical protect (usually loss of vertical from the source) 1. Shutdown at power with self diagnosis error 2-2. Check for open fuses F9A04 and F9A05 part # 283P144080 on the +24 and -24 volt lines. If the fuses are open the convergence output circuit would be suspect. 2. Shutdown at power with self diagnosis error 2-1. At power on check for 12-volts DC at connector KH pin 8, if missing check IC9C51 part # 270P990010 and L9C52 part # 441D009020 on the Signal PCB
Not finding what you are looking for?

87 views

Ask a Question

Usually answered in minutes!

Top HP Office Equipment & Supplies Experts

Cindy Wells

Level 3 Expert

6688 Answers

k24674

Level 3 Expert

8093 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a HP Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...