At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.
I have 2 DigiWeigh pocket scale. both of them are not working.. As soon as i turn the scales on it says F--H and I have know idea what that is supposed to mean... please help me to render this problem if possible. Thank you
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
It often just needs recalibrating. Try turning the scale on while holding the mode/tare button with nothing on the scale. Then press the tare button again. It should show a calibration weight which you should put onto the scale. Then it automatically calibrates.
It worked on mine,
I pushed Mode, Power, Tare at the same time.
It came up in Cal mode.
I added penny's till it was 995 or so then added small pieces paper to it till it was 100 then up popped passed. I turned it off then it works fine now.
Thank You!!!!!!!
Turn off the scale. Press and hold the MODE button and turn the scale
on. Release the MODE button you will see the scale's internal count. Press
and hold the TARE button then press (don't hold) the MODE button you
will see the full capacity is changing. Keep pressing the MODE while
holding the TARE button until you see 100.00 on the screen. The reset
is completed. You may need to recalibrate the scale after the reset.
I thought the scale was just completely broken, I was able to fix by doing the following.
1. turn unit off 2. hold down the on/off/tare AND the MODE button. 3. The unit will come up with a bunch of numbers on the screen. Release the buttons 4. Press MODE once, you will see "100" flash on the screen. if you don't press the button a second time. 5. place 100g of tare weights on the scale. 6. Press MODE button again. After this my scale said PASSED and shut off. 7. remove tare weights and turn device on. It should now register properly.
In my case. the scale was misregistering the 50g weights as 75. I shut it off. I pulled up ever so slightly on the scale plate on the hinge side of the plate are repeated steps 1-7.
I have no idea why they don't have a 3 part calibration on these.
×