Question about Nor-Lake Norlake Refrigeration 4' x 6' Kold Locker Walk-In Cooler - 6' 7'' High w/Floor

1 Answer

Ge side by side model # GSS22JEMD BB

THE UNIT SEEMS TO RUN FINE BUT THE EVAPORATOR FAN ISN'T RUNNING. ANY WAY TO TEST IT COULD IT NOT WORK BECAUSE OF MOTHER BOARD. UNIT ISN'T IN DEFROST, COMPRESSOR WORKING,
CODENSER FAN WORKING THANKS FOR ANY HELP

Posted by moneyclip on

Ad

1 Answer

David Coomer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Master
  • 1,073 Answers

YES see if you have 12 volts dc at the evaperator motor if you do then the motor is bad if you do not then the mother board is bad and ge recomends in this case to also change the fan motor at the same time

Posted on Apr 17, 2008

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Kenmore Elite Trio 795.7519 getting a code on panel "ER FF"? What's happening??


you either have a defrost problem starting or a bad evaporator fan motor or a problem with the main control board.kenmore doesn't make any products,other companies make the product and kenmore puts it's name on it,like if it starts with 106. it's whirlpool yours is 795 and that's l.g.made.from some of the sites i looked up i guess there are some serious issues with this machine like the lights staying on and causing fires and main computer board problems that you could have,next time send the full model number,let me ask you when you open the freezer door and you hear the evaporator fan running does it sound louder than normal,if not check the back inside wall of the freezer,look for frost or like snow buildup on the back wall,if so you have a defrost problem,but that error code is to do with the evaporator fan motor or freezer fan ff,i think you have a bad computer board,if you had a defrost problem the coil would ice up and you'd notice the fridge getting warm first because the evap fan can't blow the cold air from the freezer up to the fridge section and you say things are cold so the fan is running but if the computer board is bad it doesn't allow the fan to run as long as it should and it will get worse as time goes by,i would call the 800 number on the machine,tell them your problem and they might fix it for free or send you a new board for free like i say i think there's a recall on this machine and if there isn't all they can say is no we can't help you,i don't do much work on l.g. fridges but the few i've worked on it has been the mother board or main computer board same thing,also there's a tech sheet on the machine,check the front kickplate under the doors and on the tech sheet it will tell you some things to check,on the mother board there's a test button,i'll look into it for you but you press it and i think the first time it starts the compressor and you can press it three times but one of the checks is for the fan i think but i'll see if i can find it. hope this helps,one more thing can you let me know if you get this email,i've helped out other people and haven't heard back from them,just want to know if there's a problem with this site because this happened before.

Dec 29, 2013 | Kenmore 73502 / 73504 / 73509 Bottom...

1 Answer

I have a Hotpoint HSS25GFPEWW side by side.....initially the ice maker stopped crushing and dispensing ice....then the freezer started to warm. I cleaned the condenser coils and confirmed the condenser...


dead if the compressor is running and theres no cooling or frost on the evaporator you have leaked out all your freon only way to fix is call a pro about 600$ to fix

Aug 15, 2012 | Hotpoint HSS25GFP Side by Side...

1 Answer

Frigidaire GLRS264ZA refrigerator keeps blowing GFI circuit


The fan and defrost heater are run off the same relay on the board. When on defrost, the fan stops. when the fan starts, the defrost heater is switched off, Sounds like the neutral to the board may be shorting. If you have the ability, try powering the evaporator fan from the compressor relay, disconnecting from the board entirely. To see if this will work, just take a temporary wire to the fan when disconnected and see if it trips while running.

Aug 07, 2012 | Refrigerators

1 Answer

The refrigerator isn't getting cold, the freezer works fine, but this morning there was a stream of water on the floor. it seems when its hot out is when I have problems with it.


The first thing you want to do is open the freezer and see if the fan inside there is running. The reason is the freezer cools the refrigerator side by circulating air from the freezer. If the fan is running then your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

Jun 22, 2012 | Amana 22.6 cu. ft. Side-By-Side...

1 Answer

Does it make sense that a frigidaire plhs67egsb3 refrigerator freezer could stop working simply from overloading? The compressor is running, the condenser coil was clean but the evaporator coil was frozen...


the defrost heater or thermostat circuitry is bad,you need to test both components,also the defrost timer control if the other parts test o.k..,the defrost tstat has to be below 32 degrees or it will test bad/open,when the evaporator coil gets iced up you cannot blow cold air through a solid block of ice,(NO air flow)means no cold air throughout the unit even with the evaporator fan running

Apr 12, 2011 | Frigidaire Freezer FFU1212D

1 Answer

I have a GE side-by-side refrigerator/freezer that's not maintaining cold temperatures. I was told to replace the defrost thermostat which I did and it seemed to work for about a week or so. But now it's...


If the refrigerator isn’t cooling at all the motherboard is a good possibility burnt marks or not. If the fans are not running it could be a defective fan, motherboard or both. Take a look at this page http://www.appliance-repair-it.com/refrigerator-fan-motor.html

If the refrigerator isn’t defrosting properly, after a few days the freezer coils will get blocked out with heavy frost. There are four things that will cause this, defrost thermostat, defrost heater, evaporator thermistor and the motherboard. This page should help http://appliance-repair-it.com/GE-refrigerator-repair.html

Jul 17, 2010 | GE GSS25JFPCC / GSS25JFPWW Side by Side...

1 Answer

Compressor & Evap. Fan both work for 12 hours then evap stops


I believe that because defrost is done by the mother control board this is why this is happening the part of the board that controls defrost is malfunctioning and the only way to resolve the problem is to replace the mother board part number WR55X10656 You can find the replacement board at these places below. Sea Breeze

http://appliancepartsse.blogspot.com/

http://appliancepartsse.blogspot.com/

Aug 25, 2009 | GE Refrigerators

1 Answer

How do I test the defrost thermostat?


the fan is ctrl by the Jazz board the thermdisc is for defrost post your email and I will send you the manual on test process and test point as well as the defrost

Feb 12, 2008 | Amana AFD2535DES French Door Refrigerator

1 Answer

Freezer works, fan works, fridge side not getting cold


Whip, make sure the condensor fan is running in back. It should be running anytime the compressor is running. Check to see if you have a buildup of frost on the back of the freezer panel, this could indicate a defrost issue. This refer is controlled by one main mother board in back. Check these things first and post back. You may have to do some tests on the board...Catriver..post back.

Nov 24, 2006 | GE GSS25JEM Side by Side Refrigerator

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

351 people viewed this question

Ask a Question

Usually answered in minutes!

Top Nor-Lake Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4656 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Marat Brikov

Level 3 Expert

506 Answers

Are you a Nor-Lake Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...