Setting the destination Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after replacing the backup RAM on the main PCB or initializing the backup RAM by running
maintenance item U020, in order to return the setting to the value before replacement or initialization.
Enter Maintenance Mode
Enter "10871087" from keypad, You should now be in maintenance mode.
Enter "252"press "Start / Print" key.
Select your destination from list on the display.
Press "Start / Print" key.
Enter 001 "Start / Print" key to exit to normal display.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the destination using the cursor up/down keys. The selected item is displayed in reverse.
Display Description
JAPAN METRIC Metric (Japan) specifications
INCH Inch (North America) specifications
EUROPE METRIC Metric (Europe) specifications
ASIA PACIFIC Metric (Asia Pacific) specifications
2. Press the start key. The setting is set, and the machine automatically returns to the same status as when
the power is turned on.
Completion
To exit this maintenance item without changing the current count, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.