The gent set is Perkins 135 KVA after overhauled it refuses to start please the injector refuses to supply fuel to the nozzle

5 Answers

Fred Yearian

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Master 5,603 Answers
  • Posted on Apr 23, 2010
Fred Yearian
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Jul 25, 2009
Answers
5603
Questions
1
Helped
2248546
Points
16162

Check the fuel solenoid is getting power. It may be locked out by loow lube oil pressure and other things.

ALSO when restarting a diesel one OFTEN must "bleed" the fuel lines at each injector... same as when one inadvertently runs a diesel out of fuel. Crack the connectors at the injectors and crank till fuel comes out and tighten each one. Yes, it is a pain...

  • Anonymous Jun 06, 2013

    Cannot get fuel to inject with fuel pipes removed help

×

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 8 Answers
  • Posted on Jun 04, 2011
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Jun 02, 2011
Answers
8
Questions
0
Helped
6482
Points
10

Check the pump solonoid by supply it with current directly from the battery with a cable watch out for the voltage of the battery.If it is 12volt use a 12volt battery while if it is 24volt use a 24volt battery

Ad

Starlight Power

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

  • Expert 117 Answers
  • Posted on Dec 07, 2019
Starlight Power
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Joined: Jun 07, 2017
Answers
117
Questions
0
Helped
96312
Points
657

Does your Perkins generator fuel injector is burning? Have you checked that? The injector atomizes the diesel fuel and sprays it into the combustion chamber. The injector consists mainly of the nozzle and nozzle holder.

If it is fuel injector problems, you can check the problems below:
1. Long time idling operation
2. The fuel is not clean
3. Fuel injection time is too late
4. Improper assembly
5. Improper use of generator set
You can get some helps from the following articles:
https://www.dieselgeneratortech.com/diesel-generators/reasons-for-fuel-injector-burning.html
https://www.dieselgeneratortech.com/diesel-engines/Engine-Governor-Fault-And-Fuel-Injector-Fault.html
the gent set is Perkins 135 KVA after overhauled - perkins power generation-undefined-undefined-0_0.jpg

sherlywang

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Master 428 Answers
  • Posted on Dec 14, 2018
sherlywang
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Oct 20, 2017
Answers
428
Questions
0
Helped
198381
Points
1063

The diesel generator set first puts the stuck fuel injector into diesel or oil, then takes it out and wraps it in the cloth, then clamps the needle valve. The pliers move slowly. Remove the needle valve from the needle valve body, and drop a small amount of cleaning oil in the needle valve body to repeatedly move the needle valve in the needle valve body until the needle valve moves freely in the needle valve body, such as the burn surface of the needle valve. The abrasive paste should be used for grinding. When grinding, pay attention to the amount of grinding paste and grinding time. Install the cleaned valve valve connector on the injector and adjust the injection pressure for reuse.

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Aug 26, 2012
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Aug 26, 2012
Answers
1
Questions
0
Helped
653
Points
1

Check the selinoid but short cicuting it , if ok
check if diseal goes to the engine by oening injector pipe and pumping fuel
if fuel goes ok try to ut som carb cleaner in the air filter and run if it runs the pun head is worned and you must fix it

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

On a 350 kva kohler the generator whilst working cuts off and shows auxiliary fault light shows

I think you can ask your supplier, they most know their generator.
If you plan to have a new diesel generator set, maybe you can consider Cummins, Volvo, Perkins, as well as China made generator: Yuchai, Shangchai, Weichai, Ricardo etc.
Here is the website:

https://starlightgenerator.en.made-in-china.com/
0helpful
2answers

Injector pump problem

fuel filter, computer
1helpful
1answer

MF 135 3 cylinder Perkins motor. The engine sounds to be missing when under no load; under load she sounds to be firing satisfactorily. The injectors have been serviced and are said to be fine. The

Any engine runs better doing what its built for, but it should not be very noticeable. If you are familiar with this engine, then I would tend to go with your instincts. The injector timing is a likely cause and could be supplying more fuel than you need creating a laboured combustion which evens out under load.
Perkins parts were found everyware around western Australia 20 years ago and were cheap, I'm a bit out of touch on that aspect these days, but they are worth the effort, you should try to find some old school farmers around to speak with, they often have golden and unique solutions.
0helpful
2answers

Pramac 25 kva perkins encl diesel genset will not start red light on triangle on check list

Hello. Maybe you have solved your problems. But I still want to share the helpful article to you. https://www.dieselgeneratortech.com/diesel-generators/why-diesel-generator-fail-to-start.html

We are Perkins diesel generator OEM. Can provide 22KW to 2200KW diesel generator set with Perkins engine. https://www.dieselgeneratortech.com/perkins

perkins diesel generators-n5v1fnwbur1qlbncsxenjidv-1-0.jpg
0helpful
1answer

Perkins 20 kva diesel generator runs and stops in about 2 minutes.alternator failure is displayed on screen.

Ensure any engine control switch is set to the run position, with the load disengaged. Manually set the air shut off valve (if fitted) to the run position (see Fig. 18), Turn the key switch to the start position, which will energize the solenoid allowing the engine to crank over for a few seconds then start.

Check the instrument panel is showing normal running oil pressure, and the ammeter for charge to the engine batteries.
Allow the engine to run for five minutes checking the instruments are reading correctly. Stop the engine and check the oil and coolant levels, replenish if necessary.


https://www.dieselgeneratortech.com/generator-sets/normal-starting-procedure-of-Perkins-generator-set.html
0helpful
1answer

Operating Manual Perkins 550 KVA Generator

We are Perkins diesel generator OEM and can provide 22KW to 1800KW Perkins diesel generator including open type,silent type and container type genset. Each genset has its user's manual.
https://www.dieselgeneratortech.com/diesel-engines/Perkins-engines-fuel-filter-elements-and-air-filter.html

e18a26ce-0dbd-46a2-bebc-48717b237ba9.jpg
0helpful
1answer

I have a audi a3 2000 w reg 1.9tdi the problem is its hard to start in the morning when i get it started it runs perfect then if i try to start it hot the problem is the same takes a few goes to fire up ....

i think the problem is the injector pump ,this isnt common rail as yet for this age vehicle and when its starting its not throwing the auto start mechanism into play which makes it over inject fuel ,remember the old transit with the inline injector pump,lift bonnet pull throttle and push button in ,then it would go first time .well its the smae thing buts done electricaly ,only solution is to put car into a bosch injection specialist and have the pump overhauled ,lots of cash though,or use a can of brake and clutch cleaner --- and thin pipe into teh air intake and spray some of the cleaner into the air intake ,brake and clutch isnt as harsh as easy start andf their is a nozzle on the can so the pipe pushes onto that ,just like the old perkins diesels in the transits in the 60s only it was a plunger on the dash in them days .
2helpful
4answers

Its 230kvaperkins generator it starts normally,but after thirty minutes it shuts dawn automatically indicating low frequency

Low frequency means the RPM of the motor has fallen off.

Check your fuel is NOT contaminated or fuel filters plugged.

Further tests should focus on the govenor system. Possibly it fails when engine gets hot. the frequency is directly proportional to the engine speed.
5helpful
5answers

MY Perkins generator 2300 series crank but can not start

I take it it's diesel. Have you renewed filters? Bleed fuel system Make sure there is plenty of diesel flowing out of tank (pipe not blocked) Check lift pump working
Not finding what you are looking for?

663 views

Ask a Question

Usually answered in minutes!

Top Pramac Electrical Supplies Experts

littlewheel

Level 2 Expert

122 Answers

Ngoro

Level 3 Expert

3521 Answers

john h

Level 3 Expert

29494 Answers

Are you a Pramac Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...