V5 cell filter replaced - but how to reset red flashing light?
Hello,
So after you have replaced the V5 Cell Filter in the IQ Air, here are the steps you'll need to follow in order to reset the filter indicators:
You can repeat these instructions for the other two filters on your machine when it's time. Here's a link to the product manual for your IQ Air Health Pro Plus which will give you the same instructions, as well as other maintenance instructions.
http://lib.store.yahoo.net/lib/vacuumcleanerbacgs/IQAir-healthpro-plus-owners-manual.pdf
I hope that this information was helpful to you. If you were able to reset your filter, please be kind and rate the repair as helpful by clicking the thumbs up icons in the top of my repair. This is what really keeps Fixya experts continue leaving free repair solutions. Thank you very much,
Chris J.
GoVacuum
The Intelli-Check™ Filter Monitors will indicate replacement of the pre-filter and the
HEPA filter. Depending upon your individual usage (environment and hours used),
you may need to check and replace the filters more or less frequently.
To check Expected Filter Life Usage
When the unit is turned on, quickly press the appropriate filter monitor button. The
pre-filter light will flash up to 3 times and the HEPA filter light will flash up to 4 times,
depending upon how much expected filter life has been used.
PREFILTER:
1 flash = from new, up to 1/3 expected life used up
2 flashes = between 1/3 and 2/3 expected life used up
3 flashes = between 2/3 and all of expected life used up
Remains on = time to check/replace pre-filter
HEPA FILTER:
1 flash = from new, up to 1/4 expected life used up
2 flashes = between 1/4 and 1/2 expected life used up
3 flashes = between 1/2 and 3/4 expected life used up
4 flashes = between 3/4 and all of expected life used up
Remains on = time to check/replace HEPA filter
To RESET Filter Monitor
When the filter monitor light remains on, it is time to check/replace the filter and reset
the filter monitor, if needed. With the unit powered on, press and hold the appropriate
filter monitor button down for approximately 5 seconds until the light turns off.
Depending upon your individual usage (environment and hours