I have a Maytag Gemini electric stove - when I try to clean the upper oven I get the F9-4 code (which sites are saying is related to the lower oven?) When I try to clean the lower oven it works fine. When I receive the F9 -4 code on the upper oven the door appears to lock fine (I am not able to open it) and it moves to cleaning mode, but then starts to make an electical clicking noise. Shortly afterwards, the error code is displayed, the door unlocks and cleaning stops. Please let me know if you have a solution - thanks.
Its related to the self clean ltach motr, if you pull hte unit out and drop teh rear panel, approx halh way down on theright side( when behind unit) thers asmall lock mechinisn mavbe 1.5 round, with a connecting rod 2 wires and a witch, well that motor sometimes as it heats looses connection with the switch. the switch is monitoring door positoin so if it loses contact it thinks the door is open and will trigger a code. the entire latch is replacabel (FRont to back comesa sone assy latch motor swittch and rod. 2 wires connect it and 2 screws(by front latch secure it. if youtry to replaceit your self i giveyou the heads up to lie a yard stick on top of latch before removing old latch (thos will keep the insulation in place) andthen when installe ing new latch also use hte ayrd stick ontop to keep insulation inplace!!!!!
492 views
Usually answered in minutes!
I experienced the same problem today. The lower door is now locked and it will not open. Any suggestion?
started a clean cycle and noticed I left rack in.opened door to take out but door locked and now I can't close the door
self clean system will not work press both upper and lower buttons and then start and then it stops and message comes up saying "door"
cleaned oven, door will not unlock ovenis cooled down
×