At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.
This Code means low fixing unit temperature. If the power goes off and on, or Suzy Sec. has a space heater on the same circuit, this could be a false code.
Enter the service mode by keying in the numbers "10871087", on the key pad. enter the number 906, press start, press "execute"on the touch panel. The machine will reboot.
If the code comes back, you either have a bad thermistor, thermostat, or heater lamp. I have only had to replace the thermistor. The Fuser comes in the maint. kit ,so I always have some old ones laying around.
fantastico lo pude resolver sin mayor problema mi dia empezaba un poco mal pero con esto me devolvieron la alegria graciasfantastico lo pude resolver sin mayor problema mi dia empezaba un poco mal pero con esto me devolvieron la alegria gracias
You can't post conmments that contain an email address.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
C6050 Error
Abnormally low fusing unit thermistor temperature
SIM 163 Reset (only do this one SIM, by doing others you could cause your machine to no longer function. Also see note at bottom.
Entering Simulation Mode
1. Press the system menu/counter key.
2. Select Service setting using the up/down cursor keys.
3. While pressing the start key and the # key, press the enter key. (Maintenance mode is entered.)
4. Select Maintenance mode using the up/down cursor keys.
5. Press the enter key.Enter the maintenance item (163 Resetting fuser problem) number using the up/down keys.
6. Go to step 1 under method below.
Resetting the fusing problem data Description
Resets the detection of a service call code indicating a problem in the fusing section.
When a service call concerning the fusing section occurs, turn the power switch off and open the front cover.
Then, turn the power switch on and press the system menu/counter key to enter the maintenance mode.
Purpose
To prevent accidents due to an abnormally high fusing temperature.
Method
1. Press the enter key. A selection item appears.
2. Select Execute using the up/down cursor keys.
3. Press the enter key. The fusing problem data is initialized. (Four service calls, namely C6000, C6020,C6050, and C6400 are reset.)
Completion
Press the back key. The indication for selecting a maintenance item No. appears.
Note:Sometimes in order to do the reset when the machine is in an error state you need to open the top cover (like to replace the toner) and leave it open until you have performed the reset
First you must get into the service mode by keying in 10871087
The screen will start blinking - then key 163 and the screen should read cancel or execute -select execute
when it is complete turn unit off then back on and see if that worked, if not buy a new fuser unit. They cost around $150,00 to $200.00 depending on who you buy it from.
According to the knowledgebase on Canon USAs web site, System Error Exxx may be corrected by removing all power (unplug) for ten seconds, then plugging it back in.
the above is incorrect, Kyocera made a mistake by having a thermistor that physically touches the upper heat roller/belt.. it has worn the roller to a point where it throws up the error.. you will have to install a new fixing unit.
I have done over 25 warranty replacements regarding the 4050/5050/2525 etc.
This is on a Kyocera Mita KM-3035 KX
system error
reset producer
×