F1 error code is a communication failure between the outdoor and indoor units. Check all inter-connecting wires. They should be minimum 14g stranded wire. Make sure all electrical connections are tight. These units are manufactured by CHIGO, you may try to contact them.
You have to take blower out by removing the 2 screws that is holding it ,then you loose the motor shaft from wheel by using a Allen key .Once motor shaft is loose you then loosen motor frame from housing and slide motor out .Might have to spray it with wd 40 . On the housing should be some screws along the side so you loosen those and house ing would open up so you can get wheel out. To install you reverse the process. Please note the direction of the old wheel because if install backwards will not work right
×