Hello Problem with the audio (AUDIO), unit goes to standby and blinks the
self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some
projection models of Sony TV sets,
this code means that T8005 (flyback transformer), or the associative
components in the high voltage circuits are defective on the D board.Nine blinks - Replace D 6116 and D 6301 on the "G"
board, do not resolder as this will fix the problem temporary. Or Panel
Module Error or Thermal Error. If it is intermittent 9 blinks, meaning
sometimes the TV comes on and other times you get flashing, then change
the switching regulator on the "G" board or check connections. Make
sure the regulator is -12 or -13 (negitive).
shaun
Posted on Oct 23, 2009