I have worked with a technician to perform the needed service, however it appears IR does not like to give out the code needed to perform the master reset / service complete so the alarm will stop going off every 24 hours. This is for a IR Intellisys Nirvana v2.63 P/N 22199665 w/ compressor IRN75H-CC I have seen it suggested as middle button x2, then F1 then F2, service complete, but the answer was not for this specific model and I was hoping to be sure before trying that. Thank you for any help!!
Be sure to Stop/unload to compressor and wait for the display to show "Ready to Start"
To access the factory set points on an SGNe or SGNeV controller, you can access by pushing (Main Menu) twice followed by (F2) and then (F1) within a 3 seconds interval. Scroll down to (Compressor Service COMPLETED) and push SELECT, the COMPLETED will be highlighted and now push SET.
On an SG controller, the following buttons must be pushed in sequence. (Main Menu) twice followed by (Load) and (Unload) within a 3 second interval.
Performing a master reset or service complete on an Ingersoll Rand Intellisys Nirvana v2.63 VFD controller typically requires a specific code, which may only be provided by an authorized Ingersoll Rand technician or service center. However, you can try the following steps as a workaround:
It is important to note that attempting to perform a master reset or service complete without proper training or authorization can be dangerous and may cause damage to the equipment. It is always best to consult with an authorized technician or service center for assistance with these procedures.
200 views