Https://printcopy.info/?mod=erc&brand=Konica-Minolta&model=bizhub+458e&page=47
download
https://www.dsbls.com/docs/bizhub-658e-558e-458e-368e-308e_quick-guide_en_1-1-0.pdf
SOURCE: transfer unit on bizhub C250
its not so hard, open side door, remove 2 screws, and pull out the transfer unit gently. and reinstall new TBU. BE VERY CAREFUL WITH NEW UNIT, DO NOT DAMAGE IT.
SOURCE: Transfer Belt vs Transfer Roller
Its a bogus message. Simply open and close the front cover of the machine. It resets it and the message disappears.
SOURCE: how do you reset the life of the transfer unit on the Bizhub C250
Yes,
Remove Trasfert belt unit.
On the left handled remove one screw ( spring fixer) and remove right srew (over the belt / bar whit finger fixee).
Remove, on the left spring stoppage and metal handled.
Remove black little srew and take to hand fuse contact.
Change fuse (behind) with new identical fuse and reassembly.
It may be reset trasfert belt counter.
Sorry for my not good english.
Bye.
SOURCE: Where can I get instructions on how to replace the
Open right door and remove two screws holding the belt in. Lift and remove the transfer belt. After replacement run gradation.
234 views
Usually answered in minutes!
×