Question about Vulcan Heating & Cooling

Open Question

Vulcan HX100 Ducted Heater Error code 3 combustion air pressure system failure. any suggestion.

Posted by FLASM on

Ad

5 Related Answers

harjeet singh

  • 86 Answers

SOURCE: vulcan cx90 ducted heater

240 volt wiring required.

Posted on Mar 17, 2008


harjeet singh

  • 86 Answers

SOURCE: Vulcan ducted heating

not possible

Posted on Mar 28, 2008

Ad

Anonymous

  • 2 Answers

SOURCE: VULCAN BONAIRE Users manual.

Try here http://www.bonaire.com.au/support/documentation/owner/default.aspx

Posted on Jan 05, 2010

Anonymous

  • 1 Answer

SOURCE: I have an error code of E3 on my ducted air

i have an E3 error reading on my 12000 btu home airconditioner.Please let me know how to resolve this problem and get the aorcon up and running again .Thank you
Kind regards. Osman

Posted on Mar 22, 2010

Anonymous

  • 6 Answers

SOURCE: Error code 62 on Brivis Me20 ducted heater

Hi
Error 62 is related to hot surface ignitor (HSI)or/nglo module

you can check the resistance of the ignitor should be less than 10 oms @ 20 degrees

failing that, if you incomming suppy exceeds 270 volt will also result in error 62

Posted on May 15, 2010

Testimonial: "The error did indicate an HSI problem but it turned out to be a fault on the circuit board of the control module, thanks anyway"

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Bonaire gas ducted heating not reaching set room temperature anymore...


has the system air filters been serviced lately
is the system circulation fab been cleaned to allow full air circulation of the system
call in a technician to check for vermin infestation preventing the system from working properly

Jun 20, 2016 | Heating & Cooling

1 Answer

Vulcan ducted heating system 530 E (5 years old) have replaced AAA batteries on remote control but still not working. Thanks Michael


You have to recode the remote to the heater if the batteries have been removed for more than 3 minutes. On the comfort control will the remote is in a off state turn the heater off at the power.

While off press and hold the up button and the on/off until code appears then release buttons and turn the power back on to the heater.

When code disappears from the remote turn on the remote set the temp higher than current temp and combustion fan should start up then heater will fire up.

If not repeat process as they are easily corrupted by other remotes.

Download control manual from - http://www.bonaire.com.au/support/documentation/owner/default.aspx

Set / check fan speed or it may overheat.

May 17, 2011 | Heating & Cooling

1 Answer

Code 3 combustian fan error on a vulcan bonair heater


Check the exhaust and air intake for any blockage or sag that may hold some water in it. Also check the condensate hoses for any blockage. You may also want to check the small hose that goes to the pressure switch for moisture. You could also have a bad or weak combustion fan not pulling in the pressure switch.

Apr 02, 2011 | Heating & Cooling

3 Answers

We have a Vulcan Ultra high efficiency gas ducted heating


Gas ducted central heater won't switch on all of a sudden

Nov 04, 2009 | Vulcan AUW230A Heater

3 Answers

Circuit board light blinks 3 times heater will not turn on


The error code refers to a defective combustion air switch. Coleman Evcons made around 2007 had defective pressure switches or as they call them "combustion air switch". Replace it and the problem is gone.

Dec 13, 2008 | Goodman GMS90703BXA Heater

1 Answer

We have a Vulcan ducted heating unit model HX100, recently we have experienced problems with the unit where is it not heating the house, the unit goes on but blowing cold air. We have had a couple of...


  • We had the same problem with our carrier heater 4 year or so ago. We had a technician and electrician try to resolve the problem. What the tech suggest was to replace the main component board to the heater and update it as well. haven't had any troubles with it. cost was $450.

May 01, 2008 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

60 people viewed this question

Ask a Question

Usually answered in minutes!

Top Vulcan Heating & Cooling Experts

Paul Carew

Level 3 Expert

3527 Answers

Vernon Taylor

Level 3 Expert

7425 Answers

john h

Level 3 Expert

23515 Answers

Are you a Vulcan Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...