FLASM Posted on Sep 11, 2019

Vulcan HX100 Ducted Heater Error code 3 combustion air pressure system failure. any suggestion.

5 Related Answers

Anonymous

  • 86 Answers
  • Posted on Mar 17, 2008

SOURCE: vulcan cx90 ducted heater

240 volt wiring required.

Ad

Anonymous

  • 86 Answers
  • Posted on Mar 28, 2008

SOURCE: Vulcan ducted heating

not possible

Anonymous

  • 2 Answers
  • Posted on Jan 05, 2010

SOURCE: VULCAN BONAIRE Users manual.

Try here http://www.bonaire.com.au/support/documentation/owner/default.aspx

Anonymous

  • 1 Answer
  • Posted on Mar 22, 2010

SOURCE: I have an error code of E3 on my ducted air

i have an E3 error reading on my 12000 btu home airconditioner.Please let me know how to resolve this problem and get the aorcon up and running again .Thank you
Kind regards. Osman

Anonymous

  • 6 Answers
  • Posted on May 15, 2010

SOURCE: Error code 62 on Brivis Me20 ducted heater

Hi
Error 62 is related to hot surface ignitor (HSI)or/nglo module

you can check the resistance of the ignitor should be less than 10 oms @ 20 degrees

failing that, if you incomming suppy exceeds 270 volt will also result in error 62

Testimonial: "The error did indicate an HSI problem but it turned out to be a fault on the circuit board of the control module, thanks anyway"

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Evap cooler, misplaced the vulcan touchpad controller during reno, purchased a comfort control controller, i plugged in controller, its works but nothing activates evap unit to turn on.

You can check the wiring but this looks like an incompatible controller. Here are some alternatives:

If you're looking to purchase an Evaporative Cooler Vulcan Touchpad Controller, there are several options available. Here are some places where you can buy one:

The Home Depot: You can purchase a DIAL Evaporative Cooler Digital Controller from The Home Depot for $64.48.
Gasstop: Gasstop offers a refurbished wired Bonaire Comfort Control remote that works with Bonaire and Vulcan gas central heating systems for $150.
Bonaire Heating & Cooling: Bonaire offers a range of Navigator Remote Controls for Cooler and Heater, including My Climate® Wi-Fi® for ducted evaporative cooler, ducted gas heater, or dual-cycle air conditioner.

Navigator Remote Control for Cooler and Heater (bonaire.com.au)
0helpful
1answer

Vulcan Ducted Heater V5 fails to light up, 7 flashes (IGN failure)

First I would check the flame sensor is clean and the connections are all tight . Then check out the pressure switch.
0helpful
1answer

Bonaire gas ducted heating not reaching set room temperature anymore...

has the system air filters been serviced lately
is the system circulation fab been cleaned to allow full air circulation of the system
call in a technician to check for vermin infestation preventing the system from working properly
1helpful
1answer

Vulcan ducted heating system 530 E (5 years old) have replaced AAA batteries on remote control but still not working. Thanks Michael

You have to recode the remote to the heater if the batteries have been removed for more than 3 minutes. On the comfort control will the remote is in a off state turn the heater off at the power.

While off press and hold the up button and the on/off until code appears then release buttons and turn the power back on to the heater.

When code disappears from the remote turn on the remote set the temp higher than current temp and combustion fan should start up then heater will fire up.

If not repeat process as they are easily corrupted by other remotes.

Download control manual from - http://www.bonaire.com.au/support/documentation/owner/default.aspx

Set / check fan speed or it may overheat.
0helpful
1answer

Code 3 combustian fan error on a vulcan bonair heater

Check the exhaust and air intake for any blockage or sag that may hold some water in it. Also check the condensate hoses for any blockage. You may also want to check the small hose that goes to the pressure switch for moisture. You could also have a bad or weak combustion fan not pulling in the pressure switch.
21helpful
3answers

We have a Vulcan Ultra high efficiency gas ducted heating

Gas ducted central heater won't switch on all of a sudden
1helpful
3answers

Circuit board light blinks 3 times heater will not turn on

The error code refers to a defective combustion air switch. Coleman Evcons made around 2007 had defective pressure switches or as they call them "combustion air switch". Replace it and the problem is gone.
0helpful
1answer

We have a Vulcan ducted heating unit model HX100, recently we have experienced problems with the unit where is it not heating the house, the unit goes on but blowing cold air. We have had a couple of...

  • We had the same problem with our carrier heater 4 year or so ago. We had a technician and electrician try to resolve the problem. What the tech suggest was to replace the main component board to the heater and update it as well. haven't had any troubles with it. cost was $450.
Not finding what you are looking for?

171 views

Ask a Question

Usually answered in minutes!

Top Vulcan Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Are you a Vulcan Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...