Question about Precor Exercise & Fitness

1 Answer

I have a PRECOR 9.27 Treadmill with one speed. FAST! There are no errors, just very fast operation. I recently moved it and had to unplug the upper control from the lower PCA. I can lower the setpoint to .5mph and it will stop. I did a diagnostic and in the calibration test I do get a 26 Speed Error, but as above, no error in normal operation. The reed switch is good. The signal cycles up/down. The motor voltage seems very high, 125VDC (60VAC) when it does run. The PWM lamp turns on solid. Help!

Posted by Chris Regier on

Ad

1 Answer

Derrick Schultz

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Master
  • 11,405 Answers

You found the right place buddy.. i know a lot of websites for repairs and manuals that can really help u.. try www.reliable-store.com 's live assistance 24x7

Posted on Jul 10, 2019

Ad

5 Related Answers

Anonymous

  • 1 Answer

SOURCE: Maytag MAH21 - main motor won't run

Please check microswitch block door/ Best result change this microswitch on the new. If terminal is shot - longered on wire.

Rashid Moscow ([email protected])

Posted on Jan 25, 2008

Ad

cheapiephp

  • 68 Answers

SOURCE: Kenmore HE3 washer emits steady, constant beeeeeeeeeeeeeep

Depending on how your washer controls the beeper, it could be a stuck relay or a fried transistor.

Posted on Jan 17, 2009

erpaalai

Eric Duda

  • 999 Answers

SOURCE: The treadmill seems to surge or bog down when

Sounds like it needs silicone lube under the belt. Also check the deck under the walking belt to see if the shiny black coating has worn through. If it has the deck will need replaced.
Eric

Posted on Jul 03, 2009

Anonymous

  • 2 Answers

SOURCE: Help. recently cavitated my 140 hp 1989 mercury outboard motor

You may have spun the hub inside your propeller. Look between the center hub with the splines and the casting of the prop there is a rubber insert in there. See if it is distorted. The nut and washer are keeping the prop on but I think you will find if you put it in gear and try to turn the prop by hand it will spin and the shaft will not move.

Posted on Sep 19, 2009

maxtreadmill

John Mazmanian

  • 832 Answers

SOURCE: Treadmill (Vision Fitness T8500) turns on, motor doesn't run...

open motor shroud and inspect all connection on the motor control board see if all LED 's are lit except that light up when incline motor is moving up or down. then check the two connector coming from the drive motor to the board sometime over time the two connector will have a cold soldier I would move them to see any excessive movements of the pins then hit start and see if there is any belt movement. Last but not least unplug unit and check the motor brushes if they are less than 3/8 in in length replace them. Call them @ 1-800-335-4348 they under their parent corp. Johnson fitness.

Posted on Mar 01, 2010

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Error 22-23-26


Precor Error Code 23
Error Code: 23 Manufacturer: Precor
Model: All Models
Error Description: Error 23, Motor Pulses Missing after Start Up - Indication that the speed sensor signal was lost while the unit was in operation. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Incorrect gap between the speed sensor and the speed sensor target.
  3. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  4. Intermittent connection of speed sensor or drive motor wiring.
  5. Badly worn drive motor brushes not able to make proper contact with drive motor commutator.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  3. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  4. Test all wiring and wire connections of the speed sensor and drive motor. Replace or repair necessary wire connections or wiring.
  5. Inspect and replace drive motor brushes if necessary.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22
Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.

Precor Error Code 26 Error Code: 26 Manufacturer: Precor
Model: All Models
Error Description: Error 26, Motor Pulse Width Incorrect - Observation of the speed sensor signal and verification the signal from the speed sensor is appropriate for the requested speed. If an incorrect or erratic speed sensor signal is detected the error appears. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Incorrect gap between the speed sensor and the speed sensor target.
  3. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  4. Damaged speed sensor target.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  3. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  4. Inspect the speed sensor target for any scratches or tears that could cause incorrect readings. Replace the speed sensor target if necessary.
Precor Error Code 22 Precor Error Code 23 Precor Error Code 26

May 13, 2014 | Precor C964 Treadmill

1 Answer

Precore 9.31 error 23


Precor Error Code 23 Error Code: 23 Manufacturer: Precor
Model: All Models
Error Description: Error 23, Motor Pulses Missing after Start Up - Indication that the speed sensor signal was lost while the unit was in operation. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Incorrect gap between the speed sensor and the speed sensor target.
  3. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  4. Intermittent connection of speed sensor or drive motor wiring.
  5. Badly worn drive motor brushes not able to make proper contact with drive motor commutator.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  3. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  4. Test all wiring and wire connections of the speed sensor and drive motor. Replace or repair necessary wire connections or wiring.
  5. Inspect and replace drive motor brushes if necessary.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.

Jan 25, 2014 | Precor Exercise & Fitness

1 Answer

Code 22 flashed up and motor wont turn


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Nov 29, 2013 | Precor 956 Remanufactured Treadmill

1 Answer

Precor M9.35 error 22


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Nov 12, 2013 | Precor 9.35 Treadmill

1 Answer

Fixing error 22 on precor 9.33 treadmill


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Apr 14, 2013 | Precor C966i Treadmill C 966i

1 Answer

Precore m9.43 treadmill error 22


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Feb 05, 2013 | Precor 9.21 Treadmill

1 Answer

Precore m9.43 treadmill error 22


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Feb 05, 2013 | Precor 9.21 Treadmill

1 Answer

Precor 9.35 Problem--Please Help!


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Jul 21, 2012 | Precor 9.35 Treadmill

1 Answer

My Precor 9.21s trys to start then the message ERR22 comes up and it won't move. What is wrong and is it an easy/cheap fix?


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Nov 02, 2010 | Precor 9.21 Treadmill

1 Answer

Speed goes fast than slow than fast- error code 22


Precor Error Code 22 Error Code: 22 Manufacturer: Precor
Model: All Models
Error Description: Error 22, No Motor Pulses at Start Up - Error indicates that the display has sent a command for the drive motor to start, however, the speed sensor has not returned the signal acknowledging that the drive motor has started. Possible Reason:
  1. The line of sight between the speed sensor and the speed sensor target is obstructed.
  2. Badly worn drive motor brushes.
  3. Incorrect gap between the speed sensor and the speed sensor target.
  4. Incorrect adjustment of the speed sensor potentiometer (when equipped).
  5. Inoperative speed sensor.
  6. Faulty lower PCA.
  7. Faulty interconnect cable between upper and lower PCA.
  8. Faulty upper PCA.
Recommended Action:
  1. Using a static safe vacuum cleaner, carefully vacuum out the drive motor compartment. Be sure to thoroughly clean the area between the speed sensor and the speed sensor target.
  2. Bady worn drive motor brushes cannot make proper contact with the motor commutator, therefore the drive motor will not start when voltage is applied. Inspect and replace drive motor brushes if necessary.
  3. Inspect the gap of the speed sensor to the speed sensor target. Proper gap is 3/16" and the speed sensor photo eye should be aimed at the larger portion of the targets wedge shaped section. If unit has a magnetic speed sensor, the gap between the end of the sensor and the flywheel tooth needs to be 3/16".
  4. Locate the speed sensor potentiometer (when equipped) on the lower PCA. Set the speed sensor potentiometer to mid-range. Start the treadmill and increase speed to 6 mph. Carefully adjust the speed sensor potentiometer until the treadmill is operating the smoothest. Increase the speed to full speed and again adjust the speed sensor potentiometer until the treadmill is operating the smoothest. These two adjustments are typically small and are generally only a matter of fine tuning.
  5. An inoperative speed sensor will allow the drive motor to start and run briefly before the error appears. If able to access the speed sensor wiring, measure the DC voltage between the speed sensor leads. Two of the leads will always read about 5 VDC. Two will toggle between 0 and 5 VDC as you slowly turn the speed sensor target. If both measurements are not seen, the speed sensor needs replaced. Some units have the speed sensor mounted on the lower PCA and the lower PCA needs replaced.
  6. Determine if the lower PCA is bad by swapping with a known good lower PCA.
  7. Determine if the interconnect cable is bad by swapping with a know good cable.
  8. Determine if the upper PCA is bad by swapping with a know good upper PCA.
Precor Error Code 22

Oct 30, 2010 | Precor 9.31 Treadmill

Not finding what you are looking for?
Exercise & Fitness Logo

Related Topics:

128 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

NOEL
NOEL

Level 3 Expert

8546 Answers

daf62757

Level 1 Expert

31 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

34001 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others