Either the brew solenoid is bad or the shower screen is blocked or the metering jet on the top of the head is clogged.
Probably the group solenoid valve is blocked/broken.
Try taking the solenoid off, put a screwdriver through the hole and power the head.If the screwdriver sticks to the solenoid (thru magnetism) then most likely, the valve needs unblocking.
If it doesn't, the solenoid needs replacing.