Question about Freezers

1 Answer

Hi got fic upright freezer mode: suf200 . Would like to know what kind of gas does it take cause it dnt say anything on the motor or on the freezer it self

Posted by Rieyaan Hendricks on

Ad

1 Answer

Farley Redfield

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    Habit-Forming:

    Visited the website for 3 consecutive days.

    New Friend:

    An expert that has 1 follower.

  • Contributor
  • 37 Answers

The mfg is required to put that info on the model & seril plate, at least for all usa appliances. If its an import i guess anything goes, no rules. Try googel the mfg snd model number

Posted on May 20, 2019

Ad

3 Related Answers

woodchuck789

Charles T Nevin

  • 4070 Answers

SOURCE: My upright freezer won't self defrost. Frost builds up right awa

The evaporator coil behind the cover on the back wall inside the freezer will ice up under normal conditions. Every 8 to 10 hours for around 20 minutes the defrost timer (or in most newer models the electronic adaptive defrost control) will turn the defrost heater on to melt the built up ice. There is a defrost thermostat which prevents the heater from overheating the freezer by breaking the heater circuit when the temp reaches close to 32 degrees F. The entire cooling system shuts off during the defrost cycle and starts back when the timer advances through the cycle.

If this ice is not melted it will continue to build up until the air can’t flow over the coil to circulate the cold air through the freezer and into the fridge. The temperature change in the fridge is usually noticed first followed by the freezer.

If the defrost thermostat is bad it can prevent the heater from coming on OR it won’t turn the heater off when it gets too warm. It is clamped to the evaporator coil at the top to sense the temp. If it appears to be misshapen it is bad.
With an ohm meter it should show continuity when cold and none when warm.
You can also bypass the thermostat to see if the heater comes on then. If it does then you know the thermostat is bad and needs replaced.

The defrost heater is located on the evaporator. It is in a tube which is at the bottom and can also go up the sides of the evaporator. On some types you can see a burnt spot if it’s bad. With an ohm meter it should show continuity from end to end when disconnected from the wiring in the freezer. You can also test the wiring for voltage when it’s in the defrost mode.

If you have a defrost timer you can test it. It can be located under the fridge behind the kick panel on the front. Some are in the fridge with the controls at the top. You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer because that means the timer is not running. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

If you have an adaptive defrost control instead of a timer, replace it if the heater and thermostat test good. It is located in the fridge with the controls in some models and on the back in others.

If you need help finding your model number see here> http://www.appliancepartspros.com/modelnumber_locator.aspx

To locate your timer, motherboard, control or adaptive defrost control , enter your model number and search for the part or post back on Fixya.
http://www.searspartsdirect.com/partsdirect/index.action?psid=26129238&sid=PSx20071217x00001a

Posted on Sep 19, 2009

Ad

Raz Mataz

  • 389 Answers

SOURCE: Maytag upright freezer with self defrost. The water line freezes.

This sounds like your defrost heating coil has gon bad. Not much you can do but replace it. Please leave a good thumbs up for me for the effort. Pretty sure I'm correct on this one. The Raz Shack

Posted on Apr 21, 2010

solver2010

  • 923 Answers

SOURCE: Hi, Where can I buy this kind of relay. I need 1 for my upright freezer Thx, Nolie

May I suggest you try the following link?

https://www.repairclinic.com/

Posted on Apr 19, 2017

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Sides and top hot to the touch


dear sir/madam'

i think its low gas problem so kindly contect to your sevice technician for refill refrigerent gas and also change freezer,s door seal ,

thank you
hope answer the question

please vote!

Jul 30, 2010 | Frigidaire 20.3 cu. ft. Upright Freezer...

1 Answer

Freezer LFFH21F7HW upright is making to much noise when it runs. Is this an ongoing problem?


Hi, What kind of noise is it making?

Also have you tried moving the fridge slightly incase its up against a unit or sitting uneven as this can cause a noise if after this you still have the noise their isnt much you can do about it as its not worth replacing parts that are working fine.

I would move the fridge slightly or adjust the legs so its sitting even as this can cause a vibrating noise.
Let me know how you get on or if you need further assistance ok

Aug 11, 2009 | Frigidaire 20.6 cu. ft. / 583 liter...

1 Answer

Got another question about a freezer


I have seen freezer stop working because the owner pulled it out to clean behind it and pushed it back into place too far. This "Chocked" the air flow around the condenser and caused the failure. Be sure condenser is clean and air can circulate. Older units have coils up the back and newer ones have them underneath and utilize a fan. You can use a vacuum on the the underneath ones. Be sure fan runs under there.

Jan 07, 2009 | Freezers

1 Answer

Kenmore freezer


Hi Robert,
Happy to help.

You need a new door seal.
But they are not easy to put on properly

I would advise you on this occasion to call service.

These guys are good!
A&E factory service does most brands warranty services.
They are open 7days/24hours nation wide.
call tonight! 1-800-905-9505

I am happy to assist you!
Neil
PS. Before you leave this site please leave a "Problem Solved" rating for me on fixya.com

Aug 23, 2008 | Kenmore 13.7 cu. ft. / 388 liter Upright...

1 Answer

My freezer is stuck in defrost mode causing the alarm light to remain on


My freezer wouldn't run and I did find there was a reset button on the back of the freezer where the chord runs into the switch.

Jun 09, 2008 | Frigidaire 13.7 cu. ft. / 388 liter...

1 Answer

Kenmore upright freezer


1)forget about the key you'll be disposing of this unit anyway
2)the alarm is to tell you that the unit is above ideal temp.
3)the unit isn't making temp due to refrigeration issue. if it isn't cold enough on 3 then 1 won't do it either.

Apr 09, 2008 | Kenmore 20.3 cu. ft. / 575 liter Upright...

Not finding what you are looking for?
Freezers Logo

Related Topics:

204 people viewed this question

Ask a Question

Usually answered in minutes!

Top Freezers Experts

Dennis Boxerman

Level 3 Expert

1305 Answers

Muntejaya Ginting
Muntejaya Ginting

Level 3 Expert

10422 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Are you a Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides