I have a American standard tub with 752857-300 pump that shuts off an on every 5 mins took it out an run it an it runs fine what could be causing this

Posted by Joseph Krach on

Ad

5 Related Answers

Anonymous

  • 7 Answers

SOURCE: Whirlpool pump only buzzes.

Well there are two things....You say "buzzes?" Like pump is running "humming" & not pushing water. That would be an "airlock" in the pump & it needs to be primed.
If it's "buzzing" & pump motor is not turning (Like it's froze) you might have a bad start up capacitor on the pump that needs to be replaced. Worst case scenerio entire pump needs replacement.

Posted on Jan 14, 2009

Ad

Anonymous

  • 125 Answers

SOURCE: I bought American Standard whirlpool

no manual. Sounds like the motor is no good. What model and brand of pump do you have?
replacement Bath Pumps

Posted on Feb 24, 2009

Ad

Anonymous

  • 125 Answers

SOURCE: pump is running ever 5 minutes. The heat in the

Sounds as if the 'mode' for the tub is set to sense the temperature of the water. see if there is a setting on the control box to a 'timed' setting for filtering and heating instead of controlled by the temperature setting. the problem is the the control box is away from the water and when it calls for heat it is because the water is cooler there than in the hot tub. so when it calls for heat and the water starts to circulate it gets the hot water from the body of the hot tub and then shut down because it senses the 'hot water'. make sense?

Posted on Feb 26, 2009

Anonymous

  • 1 Answer

SOURCE: single knob for shower and tub wont stop running

I had the same problem, you need to shut off your valves and remove the handle that turns the water on and off. You need to turn the chrome front piece counter clockwise to remove it from the front of the unit. Pull the ball out and you should see 2 rubber o-rings with springs inside. My guess is that you have a bad o-ring that should be replaced. After you buy the kit from your local Home Depot, Lowes etc, you install the pieces the same way you removed them!

Posted on Jul 01, 2009

Anonymous

  • 193 Answers

SOURCE: look below

make sure air and fuel filter are clean.Set pump pressure to mfg set pressure after two minutes of operation

Posted on Sep 28, 2009

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

Heat works until thermostat calls for aux heat, then blower shuts off with outside unit still running.

Some blowers shut off depending on the system. Do you have electric hest strips inside? If not the blower will shut off. The outdoor fan should not be running if in defrost mode. If you have heat strips then you likely have low voltage wiring crossed

If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79

0helpful
1answer

My 90 fzr 1000 will run fine for about 10 miles then it shuts down with no warning.after siting 5 t0 10 min it starts and shuts down mutch sooner from then on.

Check the fuel filter, and fuel pump.a plugged up filter will overwork the pump, overload will get the pump too hot and shut it down
another problem could be overheating ignition module, caused by incorrect resistance replacement ignition coils. look up the proper resistance's for your bikes coil's
Jul 22, 2013 • Motorcycles
0helpful
1answer

1994 f150 6 cyl engine shuts down every 10 min restart after 5 min

Sounds like the module inside the distributor. Have to be replaced.
0helpful
1answer

We are an electrical contractor. A client asked

There arn't any provisions for ejecting water out of the pumps that i know of. The pipes are installed on the tub so that they will gravity drain back into tub. The pump wouldn't be able to run unless fully submersed in water above the jets, i mean it will but not for long. I would sugest disconnecting elec. to pump until you resolve the issue or else the pump will burn.
-This sounds like some kind of air switch problem. Something is causing the air switch to sense the air pressure excerted through the air hose without the button being pushed. This is the only thing it really could be since the power to the pump goes through this switch. I cant imagine anything else causing this other than a faulty air switch on the pump itself. This would mean the pump would need to be replaced since the air switch is sealed in place at factory. Unless some how, some way, air pressure is increasing in the air hose all by itself, not likely. But check the air hose connections on the pump and the button on the tub, if you can even see it. The hose may be partially attached and any slight movement while partially attached could push air into the switch but thats kind of a long shot. I dont know if a craked or split air hose could cause this to happen but i guess its possible.
-If i had to bet on it i would definatly say the pump switch is defective.
Good luck!.............T.Wood CFE Plumbing
0helpful
1answer

American Standard toilet constantly runs

The rubber cork thst lifts when you press the handle is leaking by and causes the water level to drop below shut off level so it trys to maintain the the shut off level every minute or so. Replace the cork with one made with the red rubber. good luck
1helpful
1answer

Pump is running ever 5 minutes. The heat in the

Sounds as if the 'mode' for the tub is set to sense the temperature of the water. see if there is a setting on the control box to a 'timed' setting for filtering and heating instead of controlled by the temperature setting. the problem is the the control box is away from the water and when it calls for heat it is because the water is cooler there than in the hot tub. so when it calls for heat and the water starts to circulate it gets the hot water from the body of the hot tub and then shut down because it senses the 'hot water'. make sense?
2helpful
2answers

Water Temperature Fluctuates

no the tub faucet is the only faucet that is wide open you might have to not run full blast on the faucet , your tankless water heater is under sized for the application, to many gallons per min going thru the unit, look at the rating chart for your unit, the r94 is only 9.4 gallons per min, and a tub faucet can be upto 5 gallons per min, depending on the faucet,,
0helpful
1answer

I have an american standard air tub and cannot get the air jets to shut off.  They turn off, but come back on automatically a short time later.  How do I shut the power off?

Check the air vacuum switch and line as you may have a air vacuum leak. The button that controls the on and off to the jets is an air vacuum switch....It may have a slow air leak in the line or connections that is activating the on and off control
1helpful
1answer

We purchased an american standard whirlpool corner tub, installed it and 5 minutes after plugging it in the heater somehow turned itself on and caught on fire almost burning down a brand new home and the...

Usually there is a safety pressure switch that requires there to be water in the tub and the pump to be running before it will allow the heater to come on. Either this switch was faulty or the controls for the tub were wired incorrectly, that's about all it could be
Not finding what you are looking for?
Home Logo

Related Topics:

258 views

Ask a Question

Usually answered in minutes!

Top American Standard Home Experts

Mike

Level 3 Expert

4379 Answers

john h

Level 3 Expert

25714 Answers

Ekse

Level 3 Expert

13435 Answers

Are you an American Standard Home Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...