Fixing Film Unit engagement / disengagement error..
Remedy
Possible cause is overload or rotation failure of the motor due to an electrical trouble 1. Check if the Fixing Assembly is installed. 2. Remove and reinstall the Fixing Assembly 3. Check the gear 4. Replace the Fixing Assembly 5. Check the harness/connector between the DC Controller PCB (UN09/ J210) and the Fixing Motor (M17). 6. Check the harness/connector between the DC Controller PCB (UN09/ J12) and the Fixing Pressure Release Sensor (PS24) 6. Check conduction of FU1153 in the AC Driver PCB (UN14) => Replace the AC Driver PCB (UN14) in the case of disconnection. 7. Replace the Fixing Motor (M17) 8. Replace the DC Controller PCB (UN09)
SOURCE: how to repair error code E000196-0001?
Error in DCON ROM
Update the set of main controller firmware.