Question about Konica Minolta Office Equipment & Supplies

1 Answer

How do I rest a drum on konica minolta C554e

I have replaced a drum on Konica Minolta C554e but its still showing replenish drum unit

Posted by thabang mollo on

Ad

1 Answer

Norman J Weimar Jr

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Konica Minolta Master
  • 6,958 Answers

Then the drum you replace is not new there is a chip on it which tell the copier its new

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Posted on Mar 04, 2018

Ad

5 Related Answers

Dan Hudson

  • 118 Answers

SOURCE: Konica Minolta Magicolor 2400W drum cartrige-how to replace?

Did you buy a whole new drum unit, or just change the cartridge? If so, the fuse may still be blown. Also, you may need to empty the spent toner out of the old cartridge.

Posted on Nov 18, 2008

Ad
taminol

taminol

  • 62 Answers

SOURCE: Hi In our office Konica Minolta C250 ,it show message mulfunction. error:- c0206

Hi,
C-0206 relates to tray 3.
With the copier turned on do the following
Open paper tray 3, remove paper, close tray, open then shut front door, load paper into tray 3 - hey presto!!
If the fault comes back you could have paper stuck behind the tray or have a defective lift up motor.
Regards
Taminol

Posted on May 27, 2009

Darek Goral

  • 51 Answers

SOURCE: konica minolta bizhub

whot is the error code and whot model of bizhub u have???

Posted on Aug 30, 2009

Anonymous

  • 13 Answers

SOURCE: Reset Chip on Konica Minolta 8031 Imaging Unit

I can provide you with a programmer to reset the chip. They are only about $500-$700. Still interested?

Posted on Sep 13, 2009

yahousewife

  • 99 Answers

SOURCE: how to replace drum unit for a konica-minolta

Press left side top cover release.Open top cover,open cartridge >open drum unite.

Posted on Dec 12, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Hi all. I've been having a problem with my bizhub c554e that i've been working on. which is when i change the drum core (K) and also the drum blade, the printing for (K) became not satisfiable. which is...


Black drum for the 554e is the same as the c364. Replace the drum as OEM not third party and DONT do it your self replace the whole drum from a Konicaminolta and the developer unit also

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

May 10, 2018 | Konica Minolta bizhub Office Equipment &...

1 Answer

MY KONICA MINOLTA BIZHUB 283 SHOWING MESSAGE REPLACE DRUM UNIT


have a tech come out and replace. you cant buy it. it is done with a drum cleaning blade and developer buy each part

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

May 27, 2017 | Konica Minolta Office Equipment & Supplies

2 Answers

Bizhub c224e error code 2558


Konica-Minolta bizhub C224e Code: C2558

Description

Abnormally high toner density detected black TCR sensor
The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times.

Remedy

1 Reinstall developing unit. 2 Reinstall toner cartridge. 3 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16, CN10 for proper connection and correct as necessary. 4 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 5 Replace the developing unit. 6 Replace FRB. 7 Replace PRCB.

http://www.printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20C224e&code=C2558

Aug 22, 2016 | Konica Minolta bizhub Office Equipment &...

1 Answer

Konica minolta bizhub C253 is showing me trouble code C- 2556. What should I do to pix this problem


Konica-Minolta bizhub C253 Trouble Error Codes List page 4

Code C2556
Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively. • When the connector of the TCR sensor is disconnected.
Solution:
1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 M3, M4 operation check (At this time, IU must be non-installation.). 4 Change imaging unit. 5 Change PRCB
Extract from:
http://www.printcopy.info/?l=en&mod=free&chap=erc&brand=Konica-Minolta&model=bizhub%20C253&page=4

Nov 14, 2015 | Konica Minolta Office Equipment & Supplies

1 Answer

Konica C554 printing colors faded. Doesn't need new cartridges. What can I do to fix it?


Hi Macalla,
The only thing that comes to mind is possibly the drum unit needs replacing. These machines are normally under a service contract. You should have gotten either a drum unit needs replacing message of toner needs refilling message on the screen. The drum replacement idea is just a GUESS!!. see link below

http://kmbsmanuals.konicaminolta.us/c554e/contents/id11-_101378852.html

Aug 03, 2015 | Konica Minolta bizhub Office Equipment &...

1 Answer

Konica minolta di3010 how can i reset drum unit?


You replace the drum and developer. Pior to that you clear counters and run the require procedures after because if you reset your drum unit without replacing it the codes will begin to show up the copier works on the counters when you clear it then the copier thinks the drum is new an set voltages as required since it is not new then you get problems . Replace the drum, cleaning blade and developer and do it right!!!!!

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Dec 02, 2013 | Konica Minolta bizhub C250 All-In-One...

2 Answers

Konica/Minolta biz 350 C2557 after replacing DV unit and drum F8


tha minolta di3510 developer unit looks the same as the unit for the konica minolta bizhub 350 but the toner sensor in the minolta unit uses a different voltage range for the toner sensor and it will throw this code make sure you have the correct unit for this machine also you can try this
go back into tech rep mode and change these settings:
select tech rep choice mode
select printer tab
select atdc sensor gain
set the value to about 165
then back all the way out to the ready screen and power the machine off then back on and replenish toner in the user management screen.

Apr 22, 2009 | Konica Minolta bizhub 250 All-In-One Laser...

2 Answers

To change opc drum in konica minolta


To Change OPC DRUM UNIT in KONICA MINOLTA 2300 w

Switch Printer Off

Open Front Door Cover

Remove Waste Toner Box

Lift Transfer Belts Blue Knob until it's placed at 11 o'clock. (it's directly behind the waste toner box)

The OPC DRUM UNIT is directly under the BLUE KNOB

SQUEEZE HANDLE and PULL OUT the OPC UNIT

Be VERY CAREFUL NOT TO SCRATCH THE GREEN COLOURED ROLLER on the OPC DRUM UNIT.

Replace new OPC DRUM and turn BLUE KNOB of TRANSFER BELT back to 7 o'clock position

Replace Waste Toner Box, Close Front Cover and Switch On.

Status Display will show OPC Drum at 100%

(You can also replace the fuse in the OPC DRUM UNIT and save yourself HUNDREDS on a new one)
I posted this on another solve problem previously, worth looking at.

Jan 06, 2009 | Minolta magicolor 2300W Laser Printer

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

200 people viewed this question

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman  J Weimar Jr
Norman J Weimar Jr

Level 3 Expert

6958 Answers

carpediemweb

Level 1 Expert

51 Answers

George Mclaughlin

Level 2 Expert

369 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions