Question about U-Line Refrigerators
SOURCE: The door was not shut
e-5 means that the unit is 10 degrees warmer then setpoint. If you just close everything up and let it run the e5 should disappear when it gets within the temperature.
Posted on May 18, 2009
SOURCE: I am getting a flashing message E5 where the temp
E5 means that the unit is 10 degrees warmer than the set point for more than 12 hours. You may need service to help you find out if its a sealed system or maybe a thermistor in the wrong location
Posted on Oct 08, 2009
SOURCE: E5 flashing error code
I have the same error on my U-Line beverage refrigerator. U-Line said the error indicates the thermostat was out of range for over 12 hours (perhaps due to a recent power outage). My fridge seems to be working just fine so I am not planning on calling a technician until something more serious breaks down.
Posted on Aug 11, 2010
SOURCE: Error Code E3 displayed on
"E3" on display for upper zone - error of DC
electric fan for upper zone.
I had an E3 on the upper zone. This fix was simple. Unscrew the 2 screws for the middle tray. Pull tray out as far as you can. Check the wires in the back, those are the wires for the fans in the back. The connectors over time corrode, and break off... All I did was connected the 2 wires that had broken off of their connector directly to each other. E3 went away and the cooler is working as it should now.in
Posted on Jun 15, 2011
897 views