How do you replace the fuse in the Sharp Carosuel II

Posted by Barbara Johnson Ryan on

  • Marvin
    Marvin Mar 15, 2017

    What fuse?

×

Ad

1 Related Answer

MicrowaveSvc

William Miller

  • 9179 Answers

SOURCE: R-4H84 Sharp Carousel II microwave oven stoped working

A microwave can be dead for many reasons.

The fuse is normally located on the floor of the chassis behind the control panel or between the door switches.

If the fuse is good, it may be an open thermostat or thermal cutout (TCO) / thermal fuse on or near the magnetron or on top of the cavity / body of the oven.

If it goes dead for a while during or after cooking then comes back on, the magnetron is probably overheating and causing the magnetron thermostat to open.

Then when it cools, it closes the circuit and allows power through again.

When checking thermostats, if it has a hood fan thermostat, that should read open, as opposed to the others, which should read closed.

If it went dead almost immediately after pressing the Start pad, that's usually a shorted high-voltage capacitor.

If it went dead a few seconds after pressing the Start pad, that's usually a failing high-voltage transformer.

If it goes dead or blows the breaker when you plug it in or open or close the door, then there's a problem with a door switch or door switch mount.

If it's intermittent or random, it may be a bad connection, usually on the control board or a loose fuse holder, or even an intermittent fuse.

You should do a continuity test on the fuse while it's in the holder (with the microwave unplugged, of course) then turn the fuse by hand or take it out and put it back in, then test it again.

If you remove the fuse, then press the meter leads against the ends, it can allow internal contact to be made and make a bad fuse appear to be good.

If you or someone you know decide to look into it, we have critical safety information and disassembly information at our site, and our link is at our listing here on FixYa: http://tinyurl.com/yzjozk

We're happy to help and we appreciate your thoughtful rating of our answer.

Posted on Jun 23, 2008

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I NEED A FREE USERS MANUAL FOR SHARP CONVECTION MICROWAVE MODEL R8570


Manuals Lib has the Operation manual for the Sharp Carousel II R-5870 here: https://www.manualslib.com/manual/987690/Sharp-Carousel-Ii-R-8570.html . If you want to download a copy of the manual, click on the Download button near the top left of the page.

I hope this helps.

Cindy Wells

Jul 16, 2018 | Sharp Microwave Ovens

1 Answer

Sharp carousel ii microwave


Turn table does not turn , sharp convection microwave R-9H84B
Can I fix this myself? or do I need to have it serviced?

Dec 06, 2013 | Sharp Microwave Ovens

1 Answer

I ave a Sharp Micro/Convection Carousel II oven. The micro works fine but the oven will not heat up , just stays warm. What part(s) might be causing this and would need to be replaced. I LOVE this...


Take off the cover and change the bid diod and the hidden fuse . You will find it on the big transformer ...and your microwafe will heat up again

Jan 12, 2018 | Sharp Microwave Ovens

1 Answer

I need a microwave timer knob for a sharp carosuel II model number R2M52B where can I find one or a replacement part that is compatable? Chris


You can go to www.applincepros.com and enter your model number and order the part you need, they also have a 800 number that costs you nothing to call and they have free shipping. You won't find the part in any local repair shops. Hope this helps you find what your looking for. Marry Xmas.

Dec 08, 2010 | Sharp Microwave Timer Knob 80QBP1089

1 Answer

R-8350, No power to touchpad, but interior light works


The touchpad has its own fuse which has probably blown due to a surge perhaps related to the turning on of the fridge. Removing the cover from a microwave is potentially lethal due to the large capacitor to drive the magnetron. However, this is usually well away from the front panel. If you do venture in you should first unplug the unit and when the outer cover is removed, discharge the large capacitor with well insulated pliers -= otherwise keep well away from it. The fuse you are interested in is on the pc board behind the touchpad. Replace it with exactly the same fuse (usually a slow blow fuse).

Sep 22, 2009 | Microwave Ovens

1 Answer

Full exact diagram of parts for sharp carousel II convention micr


Unit heat syncs and rotor is not working due to high voltage

Mar 07, 2009 | Sharp Microwave Ovens

2 Answers

R-4H84 Sharp Carousel II microwave oven stoped working


A microwave can be dead for many reasons.

The fuse is normally located on the floor of the chassis behind the control panel or between the door switches.

If the fuse is good, it may be an open thermostat or thermal cutout (TCO) / thermal fuse on or near the magnetron or on top of the cavity / body of the oven.

If it goes dead for a while during or after cooking then comes back on, the magnetron is probably overheating and causing the magnetron thermostat to open.

Then when it cools, it closes the circuit and allows power through again.

When checking thermostats, if it has a hood fan thermostat, that should read open, as opposed to the others, which should read closed.

If it went dead almost immediately after pressing the Start pad, that's usually a shorted high-voltage capacitor.

If it went dead a few seconds after pressing the Start pad, that's usually a failing high-voltage transformer.

If it goes dead or blows the breaker when you plug it in or open or close the door, then there's a problem with a door switch or door switch mount.

If it's intermittent or random, it may be a bad connection, usually on the control board or a loose fuse holder, or even an intermittent fuse.

You should do a continuity test on the fuse while it's in the holder (with the microwave unplugged, of course) then turn the fuse by hand or take it out and put it back in, then test it again.

If you remove the fuse, then press the meter leads against the ends, it can allow internal contact to be made and make a bad fuse appear to be good.

If you or someone you know decide to look into it, we have critical safety information and disassembly information at our site, and our link is at our listing here on FixYa: http://tinyurl.com/yzjozk

We're happy to help and we appreciate your thoughtful rating of our answer.

Jun 19, 2008 | Sharp R-1490 Microwave Oven

3 Answers

Sharp carousel II microwave/convection oven


The question is... Do you want to put money on a 18year MW, or put it towards a new one? I must admit I love the SHARP Combo MW Convection ovens. I own two. One is almost 25years old. The mechanical Timer Type, but they work great and I can maintain them with 30years ef exrerience. I am now retired.
It does sound like the Magnetronhas broken down, however it could be other things in the Secondary (High Voltage Side). The High Voltage Side is made up of the Secondary HV side of the High Voltage Transformer, A High Voltage Diode, a High Voltage Capacitor, and the Magnetron. The High Voltage Side is DANGEROUS, and CAUTION should be taken to protect yourself against EXTREME HIGH VOLTAGE. unplug from power and DISCHARGE High Voltage Capaciton to frame GROUND before touching anything!!!!

Jan 29, 2008 | Microwave Ovens

Not finding what you are looking for?
Sharp R-1610 Microwave Oven Logo

Related Topics:

62 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sharp Microwave Ovens Experts

William Miller
William Miller

Level 3 Expert

9179 Answers

Ekse

Level 3 Expert

13434 Answers

Gerry Harvey
Gerry Harvey

Level 3 Expert

1481 Answers

Are you a Sharp Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...