Question about Whirlpool Cabrio 7.0 Cu. Ft. Super Capacity Plus Gas Dryer

1 Answer

Sensor and computer have been replaced on cabrio dryer yet check vent light still comes on

Sensor and computer replaced yet check vent light still comes on. Dryer is 2 yrs old. This is why components were replaced

Posted by Anonymous on

Ad

1 Answer

Nater13

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Whirlpool Master
  • 610 Answers

Did you clean the exhaust duct from end to end?
Some of these have a two-belt system where the second belt turns a fan blade that resides in a plastic housing beneath the drum... the pulley will come loose and fall off sometimes which can cause this error... Help Me Find My Model Number RepairClinic com

Posted on Oct 10, 2016

Ad

5 Related Answers

Anonymous

  • 1 Answer

SOURCE: whirlpool cabrio steam electric dryer has sensor light on and does not work

have a problem with my cabrio dryer its powered on but when i push start the sense like comes on and does nother whats the problem

Posted on Oct 14, 2009

Ad

Anonymous

  • 1 Answer

SOURCE: Whirlpool Cabrio dryer won't start - the "sensing" light is on

where are the answers on those stupid site

Posted on Oct 21, 2009

Anonymous

  • 1 Answer

SOURCE: my whirlpool cabrio dryer will not turn on and the

I'm trying to replace the motor from my Whirlpool Cabrio (WED6400SW1) dryer. The motor is impossible to remove from the blower. I can't break the motor away without stripping the plastic blower nut that connects to the two. What do you recommend I do at this point. I'm thinking that I should try to seperate the two by cutting the plastic connection and order a new blower fan.

Posted on Nov 28, 2009

Jahn27

Jahn27

  • 1554 Answers

SOURCE: Whirlpool Cabrio model WED6200SW1 clothes dryer

There are two thermistors (thermal sensors) in this dryer; one is the outlet thermistor located on the blower housing and the other is the inlet thermistor located on the heating element housing as an integral part of the high-limit thermostat.
jahn27_196.jpg
jahn27_197.jpg

These thermistors are negative coefficient type and monitors the dryer temperature on their locations according to their resistance which varies inversely with the temperature. The resistance drops as the temperature rises and rises as temperature drops.

One or both of the thermistors has an open connection or high resistance which makes the electronic control board thinks that the dryer temperature is low no matter how high it is. The electronic control board then doesn't cycle the heater relay and continue to turn on the heating element. The dryer temperature continues to rise and this blows the thermal fuse.

Make sure the thermistors are connected snugly. Remember that loose or open connection means high (infinite) resistance which makes the electronic control thinks of low dryer temperature. Measure the resistance of each thermistor then refer to the tables below. Replace the thermistor if the resistance reading doesn't comply with the table.
jahn27_198.jpg
jahn27_199.jpg

Let us know if you need further advice. Please accept the solution should you find it helpful and informative. Accepting the solution will not stop you from communicating with the expert. You can still communicate with the expert should you need further advice regarding the issue stated herein.

Posted on Mar 02, 2011

Kevin White

  • 1902 Answers

SOURCE: My Whirlpool front load cabrio

Hello & Welcome to FixYa

AF means air flow and this error indicates that dryer air flow is restricted. Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check air movement. If the air movement is less than a hair dryer on high speed, clean the lint from the entire length of the system and exhaust hood, also check the outside exhaust duct. If the problem is still there after doing all this then recommended repair will be to use warranty as opening this unit voids warranty. Please get back to me if you have any other questions.

Kevin

Posted on Jun 18, 2011

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why would check vent light go on after replacing sensor and computer


Is the dryer vent blocked with lint? If there is a restriction in air flow in the vent system, the dryer will stop. Make sure the vent path is completely clean even in the wall where the vent hose connects.

Oct 07, 2016 | Whirlpool Cabrio 7.0 Cu. Ft. Super...

1 Answer

Whirlpool cabrio dryer is running, all ducts and traps are clean but no exhaust coming out of vent.


Is the fan running. Is it direct drive or belt driven.

If it's not running, you may have to replace the motor or the fan belt.

Feb 16, 2014 | Whirlpool Cabrio 7.0 Cu. Ft. Super...

2 Answers

Our Whirlpool Cabrio Elecetric dryer will not start. Model is WED6200SW1. We had just finsihed drying a load and put a 2nd load in, but it won't start. All the light come on. Could it be a sensor...


it could be that or it could be the start button, you can check the button by adding a jumper in the wires that go to it,, this should be done as a check and not left that way,, for safety

Jul 03, 2011 | Whirlpool Cabrio 7.0 Cu. Ft. Super...

1 Answer

No air coming out of the vent of two month old Cabrio.


Sounds like the vent is blocked. Pull the dryer away from the wall, remove the vent tube, and check the air passage from the rear of the machine.

Mar 01, 2011 | Whirlpool WED6200S Electric Dryer

2 Answers

Whirlpool cabrio steam electric dryer has sensor light on and does not work


have a problem with my cabrio dryer its powered on but when i push start the sense like comes on and does nother whats the problem

Apr 18, 2009 | Whirlpool ET8CHEXSQ Dryer

1 Answer

AF flashing on our Whirpool Cabrio Dryer.


Hi Terry,

AF flashes if a restricted airflow condition exists. Check to make sure the lint screen is clean, the door seal is in place and the vent is not
obstructed.
I suspect it's the vent connecting the dryer to the wall or the vent pipe in the wall to the outside. Without moving your dryer, look behind it to see if the flex duct is crushed or pinched. If it is, it's pinching off your air flow, too. Pull the dryer out straighten or replace the hose (you can get vent hose at Home Depot, Lowes or Ace Hardware) then slide the dryer back being careful to keep it about 8" from the wall (8" is the recommended distance from the back of the dryer to the wall, btw).
If the flex vent is NOT pinched off, then you should call a chimney sweep to come out and clean the vent pipe that's in the wall.

*Note---> If you want to test this diagnosis to verify it, just disconnect the flex hose from the wall and run a load of clothes. The error code should not reappear.

SG

Mar 27, 2009 | Whirlpool Cabrio 7.0 Cu. Ft. Super...

1 Answer

Cabrio Dryer keeps blowing Air Flow fuse?


Hello, yes it is possible that the thermal fuse has gone again. Before attempting any repair yourself please unplug the dryer. The thermal fuse is located in the rear of the dryer the service panel would have to be removed. it is on the hot air duct has 2 wires going to it white in colour about 1 1\2 ' s long and 1\4 " wide. Also locate wear the vent is outside and make sure you have good air flow. good luck

Dec 20, 2008 | Kenmore 62602 Electric Dryer

Not finding what you are looking for?
Whirlpool Cabrio 7.0 Cu. Ft. Super Capacity Plus Gas Dryer Logo

Related Topics:

277 people viewed this question

Ask a Question

Usually answered in minutes!

Top Whirlpool Dryers Experts

Michael Thomas
Michael Thomas

Level 3 Expert

3056 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Ned Halaweh
Ned Halaweh

Level 2 Expert

240 Answers

Are you a Whirlpool Dryer Expert? Answer questions, earn points and help others