Fisher Scientific 15-077-8 - Scientific 15-077-8 Traceable Digital Thermometer Logo

Related Topics:

seth proctor Posted on Aug 08, 2016
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Need the resistance VS temperature table for the 15-077-8 probe

Using a HP 3458 and RS925 decade resistor to apply RTD resistance or thermistor resistance and verify the digtal display reads correctly.

1 Answer

Vuk B

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Master 717 Answers
  • Posted on Aug 27, 2016
Vuk B
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Aug 31, 2011
Answers
717
Questions
0
Helped
283970
Points
1244

Http://www.omega.com/techref/pdf/z252-254.pdf

google it RTD to temp

this will not tell you if probe is reading correctly, display is just converter and calculator, probe is the one that measures and supplies result. If you have 3458A you have access to lab equipment and should ask someone how to calibrate this

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I cant get my oven to stay on model # FFEF3015LSM after a few minutes is turning oven on, it starts to beep and screen says F30

It looks like the probe is the same as the temperature sensor.

On some models, you can recalibrate the oven control up to 35 degrees Fahrenheit higher or lower. Refer to your owner's manual for instructions on how to recalibrate the oven control.

Since you're getting an error message the following may apply:

OPEN PROBE CONNECTION
1. (F30 or F31) Check resistance at room temperature & compare to RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.

SHORTED PROBE CONNECTION
2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector. .

from: Frigidaire FEFS52DSD Service Data Sheet

Possible Replacement Part:
http://www.repairclinic.com/PartDetail/Frigidaire-Range-Stove-Oven-Temperature-Sensor/316490000/1197392?modelNumber=FFEF3015LSM&fromRepairHelp=True&ss=a13b2d1284938
Mar 24, 2016 • Ovens
0helpful
1answer

Code reading is F 30 and oven not working

F 30 - Open probe connection.

1. (F30 or F31) Check resistance at room temperature & compare to *RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.

2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace *RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.

Hope this helps.
Jul 26, 2011 • Ovens
0helpful
1answer

I have a code F-30 and the oven won't work

F30 - Open probe connection

- Check resistance at room temperature & compare to RTD Sensor resistance chart.
- If resistance does not match the RTD chart replace RTD Sensor Probe.
- Check Sensor wiring harness between EOC & Sensor Probe connector.

Hope helps.
0helpful
1answer

I c f 30 on the screen what to do

F 30 - Open probe connection.

1. (F30 or F31) Check resistance at room temperature & compare to *RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.

2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace *RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.

Hope this helps.
0helpful
1answer

F30 error on kenmore elite electric stove

F30 - Open Probe connections

F31 - Shorted Probe connections

Suggested Corrective Action
1. (F30 or F31) Check resistance at room temperature & compare to *RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.

2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace *RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.

Hope this helps (remember to rate this free answer).
Jun 04, 2011 • Ovens
0helpful
1answer

What does f30 mean on the read out

F30 = Open Probe Connection

1. (F30 or F31) Check resistance at room temperature & compare to *RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.

2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace *RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.

Hope helps.
3helpful
1answer

I have a professional series frigidaire stove and it keeps showing an error code of F30. What does this mean?

Hi here is the meaning of the F30 error code. If you have any other questions please feel free to comment. Mike

F30
F31
Open probe connection.
Shorted Probe connection.
1. (F30 or F31) Check resistance at room temperature & compare to *RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.
2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace *RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.
0helpful
1answer

Power outage than code f30

Hi,

As per Manual, this Refers to Open Probe Connection.

Solutions Offered in Manual :-

1. (F30 or F31) Check resistance at room temperature & compare to *RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor wiring harness between EOC & Sensor Probe connector.
2. (F30 or F31) Check resistance at room temperature, if less than 500 ohms, replace *RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.

The chart is :-

Temperature (�F) Resistance (ohms)
32 � 1.9 - 1000 � 4.0
75 � 2.5 -1091 � 5.3
250 � 4.4 - 1453 � 8.9
350 � 5.4 -1654 � 10.8
450 � 6.9 -1852 � 13.5
550 � 8.2 - 2047 � 15.8
650 � 9.6 -2237 � 18.5
900 � 13.6 - 2697 � 24.4

Let me know, if needed further assistance.

Hope i helped you.

Thanks for using ' Fixya ' and have a nice day!!
0helpful
1answer

Error codes how to reprogram oven electric oven the code F30 appears on led display

Hi

The F-30 error code states its a Open/shorted probe connection. Check resistance at room temperature & compare
to RTD Sensor resistance chart. If resistance does not match the RTD chart replace RTD Sensor Probe. Check Sensor
wiring harness between EOC & Sensor Probe connector. Check resistance at room temperature, if less than 500 ohms, replace RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.
Also you can see the probe in the oven in the top left or right corner. It is pencil sized and about 5 inches long. You would need to get to the back of the oven to replace it. It has two 1/4 in screws that hold it in place. You then plug it into the control board and you are ready for baking again.

Please do rate this solution as FixYa and revert for further assistance.

Thanks
Rylee

1helpful
1answer

F30 Erorr on stove...

The fault code shows that your temperature probe opened.

1. Check resistance at room temperature & compare to RTD Sensor resistance chart.
If resistance does not match the RTD chart replace RTD Sensor Probe.
Check Sensor wiring harness between EOC & Sensor Probe connector.

2. Check resistance at room temperature, if less than 500 ohms, replace RTD Sensor Probe. Check for shorted Sensor Probe harness between EOC & Probe connector.

Not finding what you are looking for?

473 views

Ask a Question

Usually answered in minutes!

Top Fisher Measuring Tools & Sensors Experts

Brad Brown

Level 3 Expert

19187 Answers

Steve Pack
Steve Pack

Level 3 Expert

7121 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66831 Answers

Are you a Fisher Measuring Tool and Sensor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...