Fuser error probally needs fuser replaced and the reset as below
try this
1. Hit Additional Functions Key
2. Hit # key
3. Arrow to number 7, Printer and hit Set
4. Arrow to number 4, Printer Re-Set and hit Set.
5. Yes, re-set printer (hit minus key - back arrow).
6. Unplug the machine and plug it back in.
or this is explaination of the error and required fix from service manual.
E0000000
The reading of the main thermistor does not reach 30°C 1 sec after the main
power switch is turned on. Or, it does not reach 70°C 2 sec thereafter.
Main cause The fixing film unit is faulty. The main thermistor has an open circuit. The
fixing heater has an open circuit. The main power supply PCB is faulty. The
DC controller PCB is faulty.
Caution To reset the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Action
1. Connector
Is the connector of the fixing assembly connected?
a. main power supply PCB (J8) <-> relay connector <-> heater
b. DC controller PCB (J320) <-> relay connector <-> thermistor
NO: Connect the connector.
2. Fixing film unit (thermistor)
Check the interval between pin 1 and pin 2 and between pin 3 and pin 4 of
the connectosr (4-pin) of the thermistor for electrical continuity. Is it ¥W
(open)?
YES: The heater has an open circuit, or the thermal switch is open. Replace the fixing film unit.
4. Main power supply PCB, DC controller PCB
Press the Start key. Is the drive voltage of the heater supplied by the connector J8 of the main power supply PCB?
Main heater: between J8-1 (FSR1) and J8-5 (FSR COM)
Sub heater: between J8-3 (FSR2) and J8-5 (FSR COM)
YES: The heater drive power supply is faulty. Replace the main power
supply PCB.
NO: The thermistor control mechanism is faulty. Replace the DC controller
PCB.
1,078 views
Usually answered in minutes!
Thank you for the feedback. it worked fine. I reset it and there is not problem now. Thanks once again!
My Canon ImageCLASS D861 has a system error E000. How do I resolve the problem myself.
×