dan kelly Posted on Jan 30, 2016

How do I get my steamist steam generator to heat above the factory specification of 125 degrees? I would like to have it to 130 degrees.

1 Related Answer

protek480

Craig Butler

  • 1730 Answers
  • Posted on Jun 27, 2009

SOURCE: powermate pm0545212.02 wont generate

The exciter coil can be checked with an ohm meter. It will read fairly low ohms (probably under 100). There are diodes also. You can check them with an ohm meter too. They should read in one direction only. The red lead on the meter is + and that will conduct through the diode when your on the anode. When you reverse the leads of the meter, it should read infinite or OL.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/craig_3fa289bf857b1a3c

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

SM-9-901 Generator Steam Shower

There are three things that affect this:
1. Incoming water temp.
2. Incoming water volume.
3.Temp of the device.
There are some other minute things like humitidty and altitude too.
0helpful
1answer

I have s SM-79 unit, serial S79 23866 never used from a yard sale. I wish to use it where a previous installation had a half inch steam line, exiting at nine inch above the floor. Can I use this...

Contact company directly for product manual and help from manufacturer
http://www.steamist.com/contact.htm

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you via e-amil or phone while you work on Steamist or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

E6 Display on the control unit

You posted question under Steamist:

Sample Steamist manual says:
"Error messages E4, E5 and E6 indicate a communication problem with the steam generator. If this error occurs, check both ends of the control cable for clean, dry and secure connections.
Dirty contacts can be cleaned with alcohol and a cotton swab or a toothbrush. This can also happen if the control is not sealed and the cable connections get wet."

Error codes change as technology changes, and sample manual may not include your model:
Contact company directly for product manual and troubleshoot help from manufacturer
http://www.steamist.com/contact.htm

Add a comment for more free help.
Also take advantage of fixya expert assistance live.
For a price, expert works with you via e-mail or phone while you work on Steamist or any do-it-yourself project.
Fixya is always less expensive than a service call.
0helpful
1answer

Do I need to install a water softner before installing sm-79

you should not have to, but if the steamist is not gernerating the right amount of steam then you should put a sofftner on. you will be able to tell because it might have a hard time producing steam, but don't jump the gun right away.
0helpful
1answer
0helpful
1answer

My SM11 model Steamist was installed above our shower/steam room. It is 2 years old. While in use recently, it made a loud sound like a low-pitch popping sound or low boom. Imagine somebody inside a...

The heating elements had burned up in the unit therefor creating a dead short on that circuit. Main breakers on homes and buildings are VERY sensitive and will sometimes trip before the smaller branch cicuit breakers will . So the popping you heard was the heating elements breaking down inside the unit it can be some what noisy.
0helpful
1answer

No steam is coming out of the outlet in the steam room, but alot of water comes out of it

Check the breakers that feed power to the unit--turn off, then on. If no help, remove power from the unit and measure the resistance of the heating element--it should measure somewhere around 20 to 30 ohms, but not infinity. Hope this helps!
1helpful
1answer

Our Steamist steam shower is probably a few years

That is a main problem with the analog systems. Just not reliable as the new digital systems. To my best knowledge there is only one manufacturer making the 100% digital steam generators.
Not finding what you are looking for?

90 views

Ask a Question

Usually answered in minutes!

Top Steamist Electrical Supplies Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Steamist Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...