When the power switch is pressed the VCC 9v is measured on the 56 pin IC TB1253AN but not after a few seconds.On pin 32, the x-ray pin, about 8v appears after the power button is pressed then goes down after a few seconds. The voltage at pin 32 is supposed to be 3.3v when the TV is working o.k according to the pin diagram of the ic. The TV is being shut down by the high voltage from the x-ray protection circuit.When the TV is just plugged in the d.c voltage at the horizontal output seems to be normal at 130v. The components of the protection circuit-resistors,diodes, capacitors were checked.One end of the resistors were unsoldered. All checked o.k. The IC and the flyback transformer were replaced by new ones. Why is the voltage from the protection circuit so high? What can I do? Thank you. Donald.
TV with Black Blank Screen Repair How to Troubleshoot ...
? 3:16
www.youtube.com/watch?v=kFdVi2ejfzA
May 8, 2014 - Uploaded by ShopJimmy.com
TV Repair Help for a TV With a Black No Image on the Screen - Troubleshooting ... Click Here to BUY TV ...
899 views
Usually answered in minutes!
×