Pentair Mastertemp 460732 250000 Btu Gas Pool Heater Logo
A
Anonymous Posted on Jun 29, 2015

Do I need to replace control board on my mastertemp pool heater or could there be something else wrong?

I have a mastertemp 250; blower comes on pool light on, heating light flashes then goes out and service light comes on. I am not getting any error codes. I replaced the igniter just in case.

1 Answer

johnny rebel

Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

  • Pentair Master 10,875 Answers
  • Posted on Jun 29, 2015
 johnny rebel
Pentair Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Top Expert:

An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

Joined: May 12, 2013
Answers
10875
Questions
0
Helped
2939223
Points
47944

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

The off button on my Pentair MasterTemp 400 pool heater does not shut if off. All the other button controls work. What is wrong?

You need to replace the "membrane pad". The pad is separate from the control board. Sort of like a keyboard on a computer.
1helpful
3answers

Pentair mastertemp 250 NA. heater will not fire, no error codes. starts fine, gas flows, igniter heating but still will not fire. It has a new valve, gas pressure entering valve from new regulator is 8.35...

All appearances - No fuel to ignite!
evrything else looks good, proper gas pressure, proper volts at igniter, etc - it should ignite! If fuel present, heater should Fire!
make sure all valves are open.
Gas valve is ON
AND purge any air from gas line.
IMPORTANT ****. If you bled gas line, don't try to ignite for a few minutes. Allow gas to dissipate first, use a fan to help.
0helpful
1answer

I have a MasterTemp 250 pool heater and have notice that there is a leak (dripping) from the "drain plug" what is wrong and how do i fix it ?

some of these plugs leak from bran new about he oly thing is make sure it is clean and use red silicone on it
0helpful
2answers

Pentair MasterTemp 250 Natural Gas Heater with "Service System" issue

this heater will display 2 red light related problem 1-service the system mean you need to clean you filter, and service the heater mean it may be a problem with the heater this 2 you will be able to see it in key pad control the heater ,now reset the board and see what happens (CUT THE POWER ON/OFF UNCE )
0helpful
2answers

Power to display

check the fuse inside the control box
1helpful
1answer

No power at the control panel - MasterTemp 250

check for 24 vac at the transformer if 24 check for fuses
Not finding what you are looking for?

908 views

Ask a Question

Usually answered in minutes!

Top Pentair Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Brad Brown

Level 3 Expert

19187 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Pentair Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...