Bosch water heater

Bosch gas hot water 16Plights up all burners burn but water doesnt get hot enough as before.

1 Answer

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Scholar:

An expert who has written 20 answers of more than 400 characters.

  • Expert 73 Answers
  • Posted on Aug 18, 2009
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Scholar:

An expert who has written 20 answers of more than 400 characters.

Joined: Aug 14, 2009
Answers
73
Questions
0
Helped
70450
Points
113

I'd initially check for a cross connection (cold water leaking into hot water system). This can be done by shutting off the cold water feed to the tankless unit, then opening up hot water fixtures around the home. You should see the water come to a complete stop; if you see a steady stream of water, then you have a cross connection. The most common place for a cross connection is at single handled showers. The valve cartridge starts to fail over time.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Gas hot water heater ignites and the burner flame cones up to bottom of tank then within seconds it starts to flutter and doesnt burn correctly. It's like it drops down and burns iracticaly.

Don't know how old your hot water heater is. They don't last forever. If the tank starts to leak inside the cone it will cause the burner to do this because the water droplets will boil and splatter. Only other thing to cause this is with a cold start up when the tank is full of cold water during high humidity.
0helpful
1answer

I have a bosch aquasar 125b tankless water heater and the burners do not light when hot water is turned on this also causes the pilot light to go out

possible faulty pressure switch connected to the water line and that is failing to turn on the main gas tap solenoid
best have it checked by an accredited gas fitter or service center for the make
0helpful
1answer

Water temp flucuates from hot to cold, esspedially on very rainy days.

Gas water heater problem based on weather could imply atmospheric interference, which might indicate venting problem. Check vent specs for that model. Make sure roof or side wall vent are installed correctly, and lenghts do not exceed maximum.
Problem might also be associated with elevation setting, since water heaters are sold to match expected conditions at that elevation.
If rain is associated with cooler temperatures, and more gas appliances run at same time, then unit might be starved for gas or home does not have enough ventilation.
Problem could also indicate that tankless unit needs to catch up on yearly maintenance, including clean burner and combustion parts, check loose wiring, test ignition system, clean air intake, bleed gas line, check gas pressure and check for correct vent, etc.
Before calling service technician, open following link for Bosch troubleshooting resources including Bosch contact, typical manuals, etc.
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html
0helpful
1answer

Gas flame doesnt want to get bigger when i turn it up?

That is normal. The flame stays the same but will burn longer making the water hotter.
0helpful
1answer

I have a Bosch AquaStar AQ-125-BNG tankless water heater. It has worked very well until recently. The problem: The hot water at the tap is turned off, the flame on the main burner keeps burning and...

there is a small dia copper pipe which has a thermal coupling on it the end of it sits in the flame of the pilot light,
if it fails which it does after about 25-15 months,it shuts down the gas burner
0helpful
1answer

I have a Bosch GWH 425 HN Tankless Hot Water Heater...On 2/28/2010, it began intermittant exploding when demand for hot water occurred. Local technicians worked on the unit several times, changed and...

I have the same problem with the same model. The problem has been identified by a friend of mine, correctly, I think.
This is a very dangerous problem involving Bosch's much touted safety feature, ironically enough. IT IS THE FLAME SENSOR IN THE GAS VALVE. The flame sensor is supposed to confirm that the pilot has lighted BEFORE the main gas line sends gas to the main burners, after which the pilot shuts off. The pilot light is not coming on, the sensor that shouldn't let gas fto the main burners is failing and the main gas is flowing and ignighting from the spark that is supposed to light only the pilot in a big explosion.
This is the 2nd unit of this model that has failed. I think Bosch should do a recall
10helpful
1answer

No hot water, pilot light lights but no burner ignition

Thermo coupler may be defective. it controls the main gas valve by closing main if pilot is out. make sure thermo coupler bulb is positioned over and near tip of pilot flame, but not in the flame. Thermo couplers are inexpensive and easy to change out.
0helpful
1answer

Bosch 125BNG burners not firing

the diaphram is the pushing force for the gas valve to open, if you have a split or worn diaphram it will ned to be replaced.
0helpful
1answer

Kitchen and bathroom faucets do not get hot,hot.Lukewarm at best.

ok the way it works man is the box aka power vent the gas valve wont open until the power vent is open u can manualy open the powervent witch will open the gas valve to turn on the piolt light and in about 30 sec the main burner will kick on now if the powervent is opening the the pilot light isnt lighting then u need to replace the thurmole cuple witch sences the pilot light is on if it doesnt see the pilot the it shuts the gas valve off so it doesnt fill ur house with gas
Not finding what you are looking for?

267 views

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...