Anonymous Posted on Feb 16, 2015

I have a Frigidaire FRS26R4CWE both the Freezer (30 degrees) and Refigerator (41 degrees)were not cold enough. This a spare basement refrigerator that we use once in while. There was no ice in the bin. However, there was a chunk of ice on the back wall. I opened the back panel and found the coils with solid ice at the top. I replaced the thermostat and the defrost cycle worked good. However, the freezer is now at 27 degrees and the refrigerator is 38 degrees. I have the freezer setting at 5 and Refrigerator at 3. Any suggestion?

1 Answer

Peter Goodwin

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Frigidaire Master 744 Answers
  • Posted on Feb 16, 2015
Peter Goodwin
Frigidaire Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Oct 11, 2014
Answers
744
Questions
1
Helped
366402
Points
2777

Hello;

My name is Peter. I am a retired field service refrigeration technician.

When you removed the freezer you should have seen a even frost pattern across the cooling coils.

If you have ice at the top especially in the upper right have corner, then you either have a restriction or a refrigerant leak. In the upper right hand corner you have a very small tube with a inside diameter the size of a small needle. It is not uncommon on older units for this tube to become plugged up or leak.

A repair of this nature by a service technician would be about $550.00 USD.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

LG LFX28978 Refrigerator, freezer not cold enough, maintaing temp at 40-41 degrees.

How did you remove ice from freezer. If you uses any type of tool (Scraper etc) then you have possibly punctured the evaporator tubes. These tubes can be either as a radiator type or form part of the freezer box and are very thin therefore susceptible to puncturing when using scrapers or such to remove ice.
To remove ice from refrigerator condensers allow it to melt, you can use a hair dryer to speed this up but DO NOT use mechanical means.
0helpful
1answer

I have a Frigidaire FRS26R4CWE both the Freezer 30 degrees and Refigerator 41 degreeswere not cold enough. This a spare basement refrigerator that we use once in while. There was no ice in the bin. Ho

Hello;

My name is Peter. I am a retired field service refrigeration technician.

You are going to have to remove the back cover in your freezer. You need to inspect what is going on.

1.) Evaporator (Cooling coil) motor - If the fan motor has failed you will not get air flow through the cooling coils.
25438946-rodi0hq003gjvlyl45o52cgv-2-0.jpg
Substitution: 5303918549 Cost: $60.00
You have a old unit. This is a substitute motor. You will have to cut and splice wires to install. If you have a multi-meter, if you get 110 volts across the motor and it is not running, then the motor is bad.
A service call for this would be about $400.00.

2.) Cooling coil Iced up - If the coil is iced up you are not going to get air flow through the coil. Your defrost heater may be bad.
25438946-rodi0hq003gjvlyl45o52cgv-2-2.jpg Substitution: 5303918255 Cost: $80.00
If you have a multi-meter, set it to the lowest Ohms. If you get a reading of OL or something under 25 Ohms, then the heater is bad.
A service call for this would be around $450.00.

3.) You may have a bad thermostat - This component is mounted on the upper right had corner of your cooling coil. They explode where the back pops out. This component needs to be spliced and wired.
25438946-rodi0hq003gjvlyl45o52cgv-2-5.jpg
Part #: 5303918214 Cost: $15.00
A service call for this would be about $350.00.

4.) If all of the other components check out, then you have a bad defrost timer. It is located in your fresh food section upper left under the housing cover.

25438946-rodi0hq003gjvlyl45o52cgv-2-9.jpg
Substitution: 5303918476 Cost: $82.00
A service call would be about $500.00.

Look, you have a older unit that has substitution parts. If you are not handy do not attempt the repair.
You may wish to consider going to a Sears Factory Outlet (Scratch & Dent) Store. You can save $300.00-$450.00 on a unit, and get a one year warrantee with it.
Rule of Thumb: "If the repair cost is 1/3 or more than the original purchase price, then buy new".
0helpful
1answer
1helpful
1answer

Kelvinator Cyclic 330 not getting cold enough

Empty the refigerator and freezer, unplug it for about 8 hours, leave freezer door open so it will completely defrost. Plug it back in for 4 hours and close doors before you fill it back up with food. If you have a thermometer, check the interior temperatures before you fill it back up. Refigerator should be around 42 degrees F.
0helpful
1answer

Freezer works but refigerator won't get cold

IF YOU HAVE ALOT OF FROST ON THE BACK PANEL OF THE FREEZER IT IS A DEFROST T-STAT THAT CAN BE BAD IF THERE IS NO FROST FELL UP IN THE LEFT UPPER CORN OF THE FRIG SIDE SEE IF YOU CAN FILL THE AIR COMING OUT OF IT
0helpful
1answer

Freezer is working but refigerator has no cold air blowing

Hi,

Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling

Refrigerator not Cooling or Fridge not Cooling

How to Defrost Refrigerator
Defrost Timer Problem

Water Running in refrigerator from Freezer


Refrigerator or Freezer not Cooling or Getting Cold


heatman101



.................

1helpful
1answer

Frigidaire refrigerator with a broken freezer

He is correct. The temp in the refrig controls how often and for how long the refrig runs. Lets say the temp in your garage is 34 degrees, and you have your refrig set to 36 degrees: The refrig will never run, the fresh foods section will cool to 34, and the freezer will warm to 34. Even if the temp is 45 in the garage and you set the fresh foods to be 33, the refrig will not need to run long enough and often enough to keep the freezer temp cold enough. You will most likely need to have the ambient room temp at least 55 degrees to get satisfactory refrigerator performance. Insulating the refrig will not help. (by the way, outdoor beverage vending machines use an internal heater in cold weather to prevent liquid beverages inside from freezing,..... so using that info, you could put a low wattage heater in your refrig to make your refrig run enough to make the freezer section work. The %&#* with that, just move it into the house!)
0helpful
1answer

Comperssor kicks on but quickly cuts off intermittently every 5 minutes on my frigidaire fridge side by side

Freezer defrosted everything fan continues to run but will not freeze. Compressor is cycling enough to keep refigerator section cold. 106 Series Kenmore. Turned up thermostat to keep fridge cold and a shorter intermittent compressor cycle run
0helpful
1answer

My refigerator and freezer are not cooling enough

Is the fan in the freezer running?? Is there frost on back panel of freezer??
Not finding what you are looking for?

104 views

Ask a Question

Usually answered in minutes!

Top Frigidaire Refrigerators Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Are you a Frigidaire Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...