Question about Precor EFX 546i Elliptical Version 4

1 Answer

Reset the error code on a precor elliptical

Error code 400

Posted by Anonymous on

Ad

1 Answer

Russ Wolterstorff

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    New Friend:

    An expert that has 1 follower.

    Cheetah:

    An expert who has answered 20 or more questions within one hour.

  • Contributor
  • 60 Answers

Not familiar with an error 400 - and error 40 is an elevation error - it needs to be addressed(fixed) cannot really be reset otherwise. Check connections and fuses first. If it was recently put together, make sure the data cable was not pinched. If it is battery operated, an error 40 can occur when the battery is low.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Posted on Jan 10, 2015

Ad

3 Related Answers

Anonymous

  • 1 Answer

SOURCE: looking for repair manuals and error codes for

Could you please advice about ERROR 29 fo C956i/C966i treadmill.

Posted on Mar 04, 2010

Ad

Anonymous

  • 1 Answer

SOURCE: the resistance on my Precor elliptical 5.17 will

There is a small motor under the shroud that operates the resistance motor. It is about the size of a roll of half dollars. Have someone use a meter and check that you are getting power to this. When you turn on the machine the motor should move the resistance forward then back. You can hear this everytime you turn it on.

Posted on Mar 11, 2010

dcramer531

Dcramer531

  • 1654 Answers

SOURCE: How do I replace the

You may have to purchase the belt from a Precor dealer in you area, if you don't have one then call Precor directly @ 1-800-347-4404 and they will help you. Most of these part have not hit the secondary market yet and Precor pretty much call the shots on whom the sell parts and support to.
There is a place on line to get some of these, it is. www.treadmilldoctor.com/Products-Services2/precor-treadmill-belt.
The manual can be found at. fitness.manualsonline.com/ex/thread/view/idThread/2141832
This place has manuals and user manulas along with support and some partswww.shopwiki.com/Precor+EFX+5.171 I believe this unit has a 10 yr warranty with it and the part in question may be covered by them. There is also a 1 year part warrant for other parts, I just don't know what parts they are covering for the 10 yr.

Posted on Dec 26, 2010

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Ricoh sp C221SF Error code Sc 400


The board that controls it. Probably the IOB. Typically, the code is cause by a dirty ID sensor.

Oct 04, 2014 | Ricoh SP C221SF Aficio Printer

2 Answers

How to go service mode Cannon ir 400 ?


Here is the error code page http://www.scribd.com/doc/56428927/iR-400-Code-List
And here is the service manual
http://www.scribd.com/doc/135167936/canon-Ir-400-Service-Manual
Looking at what the error is, getting into the service mode will not allow you to fix it; you have some parts to replace first.

Jul 20, 2014 | Cannon Office Equipment & Supplies

1 Answer

What is an error code 32 on a Precor 546I


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Dec 10, 2013 | Precor EFX 546i Elliptical Version 4

1 Answer

Precor EFX 546 05 stuck key


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Jul 02, 2013 | Precor EFX 546i Elliptical Version 4

1 Answer

Key depressed error


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.
Precor Error Code 05

Nov 13, 2012 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 30 problem for 556 precor elliptical


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Mar 03, 2012 | Precor EFX 546i Elliptical Version 4

1 Answer

How to fix Precor EFX 5.17 error code 30


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Nov 01, 2011 | Precor EFX 546i Elliptical Version 4

Not finding what you are looking for?
Precor EFX 546i Elliptical Version 4 Logo

Related Topics:

662 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

NOEL
NOEL

Level 3 Expert

8549 Answers

Ngoro

Level 3 Expert

2946 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

35895 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...