MITA TA180 ERROR MESSAGE C6000
Fuser heater break
Fuser thermistor 1 detected less than
70°C/158°F for 10 s during warm-up and
ready in.
During warm-up, the temperature at the
fuser unit thermistor 1 does not rise by
1°C/1.8°F continuously for 5 s.
Fuser thermistor 2 detected less than
40°C/104°F for 10 s during warm-up and
ready in.
During warm-up, the temperature at the
fuser unit thermistor 2 does not rise by
1°C/1.8°F continuously for 5 s.
Defective fuser
heater 1 or 2.
Replace the fuser heater 1 or 2.
Installation defectiveness
on fuser
thermistor 1 or 2.
Check the mounting state of the fuser thermistor
1. If any problem is found, repair it.
Defective fuser
thermostat.
Replace the fuser thermostat.
Defective PWB. Replace the power source PWB or engine
PWB and check for correct operation
×