RTO Atwood Water Heater - 6 Gal LP Logo
A
Anonymous Posted on Jun 20, 2014

Why does bunner light then runs for a minute shuts off then shuts off

3 Answers

ttom

Level 1:

An expert who has achieved level 1.

Welcome Back:

Visited the website for 2 consecutive days.

  • Contributor 1 Answer
  • Posted on Jun 22, 2014
ttom
Contributor
Level 1:

An expert who has achieved level 1.

Welcome Back:

Visited the website for 2 consecutive days.

Joined: Sep 08, 2007
Answers
1
Questions
2
Helped
191
Points
1

If you haven't already ,check thermostat, check inline fuse, check ground wire.

bertiesar

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that hasĀ over 10 points.

Problem Solver:

An expert who has answered 5 questions.

  • Contributor 18 Answers
  • Posted on Jun 21, 2014
bertiesar
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that hasĀ over 10 points.

Problem Solver:

An expert who has answered 5 questions.

Joined: Nov 07, 2013
Answers
18
Questions
0
Helped
2185
Points
52

It needs a new thermocouple at the pilot light. This device generates a small of electric current when heated to hold the gas valve open. It is a safety device.

Ad

ray roof

Level 1:

An expert who has achieved level 1.

Habit-Forming:

Visited the website for 3 consecutive days.

New Friend:

An expert that has 1 follower.

Welcome Back:

Visited the website for 2 consecutive days.

  • Contributor 1 Answer
  • Posted on Jun 21, 2014
ray roof
Contributor
Level 1:

An expert who has achieved level 1.

Habit-Forming:

Visited the website for 3 consecutive days.

New Friend:

An expert that has 1 follower.

Welcome Back:

Visited the website for 2 consecutive days.

Joined: May 02, 2013
Answers
1
Questions
6
Helped
191
Points
1

L would check the thermocouple first then if it keeps cutting off check the gas valve.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer
0helpful
1answer

Any idea why my Atwood water heater will shut the main burner and the pilot light off at the same time? Sometimes runs for 20 minutes, sometimes 2. I hear a clicking sound, then they both shut off.

The thermostat shuts off the main burner.The pilot light gas is controlled by the thermocouple which the side of the pilot flame has to envelop. If the flame is too small or too far away from the flame, it shuts the gas off to the pilot. The thermocouple generates a small voltage which keeps the pilot gas open. It can over time fail itself, so look at replacing it. The thermostat sounds like it's failing too.
0helpful
1answer

Heater still runs after shutting off

Fan will come to dissipate any heat build up in heat exchanger
0helpful
2answers

Lound vibration when running

Check gas control valve.

Good luck,

Marty
0helpful
1answer

I have a G6A-3E heater. didn't work untill I cleaned the terminals on the t,stat It works but shuts off befor the water is hot!

Take a multimeter or 12 volt test light and probe terminals on Therm & ECO for 12 VDC power while running. When it shuts down and wateris not hot, test for voltage again at those terminals, If you have 12 volts to side of therm that goes to ECO beside it, then therm is ok, but then check opposite side of ECO as well. If power on one side of ECO, but not the other, the ECO is faulty. Simply walk across with probe testing for voltage when you find no power at one terminal but not the other, it's faulty, replace it.
1helpful
1answer

Pilot light keeps going out

pilot light keeps going out! more then likely its the thermal coupling doing this. if bad it shut all gas to heater for a safety measure. just shut power off, then turn gas off and replace it. then you should be ready to go. to relight heater hold down on gas vavle knob in the pilot position, hold down and light it at the coupling where gas comes out. when it is lit, continue to hold down for 60 seconds. release knob very slow. then if its lit, turn to the run position. if flme goes out, wait at least 5 minutes to expel the gas fumes and turn to pilot and try again. good-day !
0helpful
1answer

The hot water shuts down for a few minuts then

your unit is undersized or you do not have enough gas supply to run the unit properly.
If you have to many water features running or you have to many gas items turn on at the same time it can cause problems.
0helpful
1answer

Water heater lights runs for a minute then shuts off, what could be wrong?

water heaters run until they reach a certain temperature and then shut off, in a similar way to the thermostat in your air conditioning.
0helpful
1answer

Heater

have service completed
Not finding what you are looking for?

201 views

Ask a Question

Usually answered in minutes!

Top RTO Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a RTO Water Heater Expert? Answer questions, earn points and help others