I have checked all the usual suspects inside. thermal fuse. defrost sensor and heater and fans
Most likely the start relay on the compressor that changes from start windings to run windings. the compressor will run for about 30 seconds on start windings then click out on internal thermal overload.
this can be confirmed by turning it on and letting it do the 30 second run then when it stops just wait and see if it cuts in and tries to run again (usually takes about 5 min) the second time it cuts in it wil most likely not run for as long (usually about 10 seconds). if this is what it does get a new compressor start/run relay.
as for the fan flick it with your finger and see if it spins freely.