the e001 code is something is going with the fixing assembly. one of the thermistors could be going bad.
E808 is a Zero Cross error. We most commonly see power supplies or bad wall voltage cause this code.
The following information is coppied from the IR2016 Service Manual.
E808-0000 DRIVE CIRCUIT FAILURE
A zero crossing signal cannot be detected.
A fixing drive motor failure has been detected.
E808 0000 Fixing drive circuit failure
- The heater does not turn on.
- A fixing drive motor failure was detected.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the fixing drive motor.
- Replace the DC controller PCB.
- Replace the power supply PCB.
M201 - Fixing Drive Motor - FK2-1067 - J202 on the DC controller PCB - E007, E808
Power Supply - FK2-1074
×