Question about Hayward Pool & Spa
HS = High Limit Sensor
Heaters Maximum Water Temperature has been Exceeded.
A few reasons this occurs...
But anyway, your heaters fault code you asked about is: hs, not h5
Posted on Jun 15, 2015
SOURCE: Our Hayward gas heater keeps giving us a H5 error
Could the Error code be HS? That is high temperature limit. Perhaps you' don't have enough flow, allowing the heater to heat the water to a temperature higher, than the thermostat setting. Make sure your bypass valve is closed, allowing full flow through the heater. Check your filter pressure differential , and skimmer baskets.
You didn't give your model number, and there are many models. You can go the Hayward website below and select your exact model number and download the manual. The manual will explain each error code.
http://www.haywardnet.com/inground/products/manuals.cfm
Posted on Jul 05, 2010
SOURCE: CE error code on hayward pool heater
CE= Communication Error between Control Module
and Display Interface Assembly
1. Disconnect and then reconnect power to heater.
2. Check for faulty wiring or connection.
Inspect Display Interface Wiring. Ensure Display Interface Plug is securely attached to Control Module. .
3. Control Module and/or Display Interface Assembly
are defective.Replace Control Module and/or Display Interface Assembly.
Here is a linkt oH aywardmanuals:
http://www.haywardnet.com/inground/products/manuals.cfm
Posted on Jul 05, 2010
Mar 05, 2017 | Hayward Pool & Spa
Oct 02, 2014 | Hayward Pool & Spa
Jun 10, 2014 | Hayward H Series Pool & Spa Heater...
May 25, 2014 | Hayward H-series Electronic Gas Pool...
May 16, 2012 | Hayward Pool & Spa
Jul 05, 2010 | Hayward Pool & Spa
Mar 05, 2009 | Hayward H Series Pool & Spa Heater 400k...
460 people viewed this question
Usually answered in minutes!
Yes thank you very much TOM W. That was the problem. The bypass valve was open on mine and gave me the HS error. Turned the bypass valve off and worked beautifully.
Thanks again.
×