1 Answer

My BM23 turns on when I turn the thermostat up but the evap fan does not turn on. Should the evap fan run all the time or only when the thermostat turns the compressor on?

Posted by Anonymous on

Ad

1 Answer

akersken

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 187 Answers

The evap fan runs continuously if the thermostat is not in the off position. If the fan is not running you need to find out if it is getting power and replace it if necessary.

Posted on Oct 21, 2014

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Beverage Air Sur 60 and unit powers on the inside fans run also the compressor and fan in the back run but unit doesn't ever cool down any ???


first are the evap coils one big ice block? if so melt the ice and look for a air gap in the door gasket. the comp. turns on so the thermostat is sending the signal to turn on. on these the drain from the evap (cold part/ top) could be blocked. blocked drain, water sits, then freezes and blocks air flow

Apr 08, 2014 | Refrigerators

1 Answer

Bevair pizza unit gets to 50 degrees. What I did and noticed. I can't find a serial number so not much help there. Cleaned coils, fan and all machine. Noticed fan motor never stop running. Seem compressor...


you should hear a click when going to the off position and another click when turning on or take it out and measure resistance on both position with a multi volt meter with beeping sound.

Oct 23, 2013 | Beverage-Air BM23

1 Answer

Beverage Air Kegerator Runs constantly gets too cold


yes sounds like a bad defrost terminator or timer?
not allowing it to go into defrost so compressor runs all the time and it frreezes up




17932314-j0bg5my5wcxq3jsayeotzht3-1-0.jpg

17932314-j0bg5my5wcxq3jsayeotzht3-1-2.jpg

17932314-j0bg5my5wcxq3jsayeotzht3-1-5.jpg

17932314-j0bg5my5wcxq3jsayeotzht3-1-9.jpg

17932314-j0bg5my5wcxq3jsayeotzht3-1-14.jpg

17932314-j0bg5my5wcxq3jsayeotzht3-1-20.jpg

Apr 29, 2013 | Beverage-Air Refrigerators

1 Answer

The evaporator fan is not working. Is there a schematic online for this Refrigerator?


Hello,
I am not sure if their a schematic online for that brand but the circuit is going to be like this

120 volts at plug
neutral side of fan wired directly at all times
Hot side from plug into thermostat
out of thermostat into defrost timer
out of timer to evap fan motor
hot from,plug to t-stat to defrost timer finally to evap. fan plus neutral side at evep motor makes it run

Aug 15, 2011 | Sanyo SR1031S Refrigerator

1 Answer

I have an amana ASD2626hes side by side refer/freezer unti. REcently it soppted colling in the refer and the freezer was cold on the bottom only - top warm. I pulled the freezer inside coer - found the...


Hi,
It could be either....
It is best to check and see if you are getting power to the fan...power to fan, the fan is bad...no power the board is bad...

heatman101

Apr 23, 2011 | Amana Refrigerators

1 Answer

I'm replacing the thermostat on a BM23c. The old one has 2 prongs with 2 black wires hooked up. The new thermostat has 4 prongs, 2 on each side. how does it get wired? Also, someone ran a black wire to the...


Not familiar with this thermostat but you can figure it out if you know how to use a meter. Sounds like they want you to run both power and neutral threw the thermostat OR it is one that either opens on temp rise or closes on temp rise. Also, the wire tapped into the black one for the fan is probably to energize the fan 24/7 as the original may have been damaged.

Jun 17, 2017 | Beverage-Air BM23

1 Answer

Frigidaire Freezer, model # FFU20FC6AW3. Unit is not cooling and the fan motor inside behind the access panel is not running. My Temperature Alarm sounds and will not shut off, unless I switch it to the...


if the evap fan is not turning try to turn it by hand a few times then start you freezer if it does not turn it needs to be replaced.make sure there is no ice build up on the evap coils.alos check the continuity of the defrost heater below the evap coils.once you het teh fan replace your unit should cool down to the proper temps.

Nov 16, 2010 | Frigidaire Freezer Refrigeration White...

1 Answer

Unit not freezing , evaporator fan wont run


If this is a Bev-Air, don't think the door switch will control the fan. At the evap, there is a temp sensor called a fan delay. When unit goes into defrost mode, this warms up. Some also serve a dual purpose. It will terminate the defrost cycle at a certain temp., say 51 degrees or so, at the evap. Anyway, when unit comes out of defrost, it keeps the fan off so it allows the evap to cool quicker and to prevent circulating warm air. This could be your problem. Not a hard fix but they can be a pain sometimes. Outside chance that the unit is low on refrigerant (freon). This will not let the evap get cold enough to trip the sensor back into position to turn the fan on. Good Luck. Restaurant Parts and More carry alot of Bev-Air stuff. 1-888-814-1110. Ask for Rick

Oct 09, 2008 | Beverage-Air 23.1 cu. ft. / 654 liter...

Not finding what you are looking for?
Beverage-Air BM23 Logo

Related Topics:

134 people viewed this question

Ask a Question

Usually answered in minutes!

Top Beverage-Air Refrigerators Experts

Dennis Boxerman

Level 3 Expert

1303 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Paul G
Paul G

Level 2 Expert

161 Answers

Are you a Beverage-Air Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...