Try this:
This will reset the code. If the code appears again you will need either a new fuser lamp or thermisters.
6030 Broken fuser thermistor M wire
*35/37 and 45/47 ppm printers (EUR/
USA model) only
Input from fuser thermistor M is less than
1 (A/D value) for more than 3 s.
Poor contact in the
fuser thermistor M
connector terminals.
Reinsert the connector (See page P.1-5-19).
Broken fuser
thermistor M wire./from the manual try replacing thermistors then reset the code or just replace fuser then reset the code
from the manual sadjnbdsvknsdlkvnsdv
6030 Broken fuser thermistor M wire
*35/37 and 45/47 ppm printers (EUR/
USA model) only
Input from fuser thermistor M is less than
1 (A/D value) for more than 3 s.
Poor contact in the
fuser thermistor M
connector terminals.
Reinsert the connector (See page P.1-5-19).
Broken fuser
thermistor M wire.
Try replacing the thermosters then reset the code or just replace the fuser and reset the code
×
SOURCE: What type of corona wire is used on Kyocera
The service manual does not specify but you will probably be ok with tungsten or oxidized. If the copies look bad with one try the other. The main charge is replaced as a whole charge assembly so I can't say that I have had to restring one.
588 views
Usually answered in minutes!
×