Cyan TCR Sensor adjustment failure

I installed all new imaging unit chip and have gotten the error code c- 2559, installed another new chip and still get code.

1 Answer

Norman Weimar

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Konica Minolta Master 7,035 Answers
  • Posted on Jan 24, 2016
Norman Weimar
Konica Minolta Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 09, 2009
Answers
7035
Questions
2
Helped
1908822
Points
11959

Replace the image unit code has nothing to do with the chip!!!

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

3 Related Answers

Anonymous

  • 13 Answers
  • Posted on Sep 13, 2009

SOURCE: Reset Chip on Konica Minolta 8031 Imaging Unit

I can provide you with a programmer to reset the chip. They are only about $500-$700. Still interested?

Ad
xeerie

Zaheer Ahmed

  • 347 Answers
  • Posted on Jul 06, 2010

SOURCE: TRYING TO REPLACE IMAGING RESET CHIP BIZHUB C550

watch these videos........


Adorjani Laszlo

  • 1316 Answers
  • Posted on Feb 11, 2013

SOURCE: Error code 2557

C-2557 Abnormally low toner density detected black TCR sensor.The TC ratio in the developing machine wich is determined by toner replenishing amount control mechanism is 5% or less for a given number of times consecutively.
Relevant electrical parts:imaging unit K,toner supply motor C/K ,mechanical control board or MFP control board.
Perform image troubleshooting procedure if image density is low.
Clean the TCR sensor window on the underside of the imaging unit if dirty.
Check the toner supply motor operation.
Remove and reinstall imaging unit K. or change the imaging unit.
Last solution turn ON the copier open the front door ,enter in service mode,select sistem1 or 2 ,select IuU Unit,select Unit K ,select new release press start and after job is completed close the front door,turn OFF the power,wait 2 minutes and turn ON.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

Konica minolta C8000 getting error code c2453

cyan tcr check add new developer, or bad TCR sensor located under developer unit or worse case main board

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

0helpful
1answer

Error code 2557

C-2557 Abnormally low toner density detected black TCR sensor.The TC ratio in the developing machine wich is determined by toner replenishing amount control mechanism is 5% or less for a given number of times consecutively.
Relevant electrical parts:imaging unit K,toner supply motor C/K ,mechanical control board or MFP control board.
Perform image troubleshooting procedure if image density is low.
Clean the TCR sensor window on the underside of the imaging unit if dirty.
Check the toner supply motor operation.
Remove and reinstall imaging unit K. or change the imaging unit.
Last solution turn ON the copier open the front door ,enter in service mode,select sistem1 or 2 ,select IuU Unit,select Unit K ,select new release press start and after job is completed close the front door,turn OFF the power,wait 2 minutes and turn ON.
1helpful
1answer

How to solve error c2551 in Konica bizhub c220

C 2557,C 2558 Black TCR sensor.
C 2551,C2552,C 2559 Cyan TCR sensor.Check de consumabile life,if you have possibility change the Black and Cyan Imaging unit.Enter in the service mode Press Utility key - Metercount- Details- Stop 00 Stop 01 select Sistem 1 or Sistem 2and read the messages.For reset turn OFF the copier,press and hold the Utility key turn ON the copier and then the display appaire Trouble reset release the Utility key and touch the reset,turn OFF the copier wait 2 minutes and turn ON.
0helpful
2answers

Error code c-255a

C255A: Magenta TCR sensor adjustment failure



1 Reinstall imaging unit
2 Change imaging unit
3 Change PRCB
0helpful
1answer

What is c2559

C2559: Cyan TCR Sensor adjustment failure



Clean the TCR Sensor window on the
underside of the Imaging Unit if dirty



or


Change Imaging Unit


6helpful
1answer

Printer displays c-0096 on display

C0096 Image Transfer Belt pressure/retraction failure

please have this services as this is a part of the printer that is not consumable.

Code Item
C0000 Main Motor’s failure to turn
C0001 Main Motor turning at abnormal timing
C0016 Bk PC Motor’s failure to turn
C0017 Bk PC Motor’s turning at abnormal timing
C0018 Color PC Drum Motor’s failure to turn
C0019 Color PC Drum Motor’s turning at abnormal timing
C001A Color Developing Motor’s failure to turn
C00l B Color Developing Motor’s turning at abnormal timing
C0040 Suction Fan Motor’s failure to turn
C0046 Fusing Cooling Fan Motor/1 failure to turn
C0048 Fusing Cooling Fan Motor/1 or Fusing Cooling Fan Motor/2 failure to turn
C004C Ozone Ventilation Fan Motor’s failure to turn
C004D Toner Suction Fan Motor’s failure to turn
C004E Power Supply Cooling Fan Motor’s failure to turn
C004F Cooling Fan Motor 2’s failure to turn
C0060 Fusing Drive Motor's failure to turn
C0061 Fusing Drive Motor turning at abnormal timing
C0094 2nd Image Transfer Roller pres-sure/retraction failure
C0096 Image Transfer Belt pressure/retraction failure
C0098 Fusing Pressure Roller pressure/retraction failure
C0200 Cyan PC Drum Charge Corona malfunction
C0202 Magenta PC Drum Charge Corona malfunction
C0204 Yellow PC Drum Charge Corona malfunction
C0206 Black PC Drum Charge Corona malfunction
C0208 PC Drum Charge Corona malfunction
C0400 Exposure Lamp’s failure to turn ON
C0410 Exposure Lamp turning ON at abnormal timing
C0500 Heating Roller warm-up failure
C0501 Fusing Pressure Roller warm-up failure
C0510 Heating Roller abnormally low temperature
C051 1 Fusing Pressure Roller abnormally low temperature
C0520 Heating Roller abnormally high temperature
C0521 Fusing Pressure Roller abnormally high temperature
C0650 Scanner Home Sensor malfunction
C0660 Scanner overrun failure
C0900 Tray3 Elevator failure
C0910 Tray2 Elevator failure
C0950 Tray4 Elevator failure
C0960 Bypass lifting motion failure
C0990 LCT Elevator Motor malfunction(Elevator malfunction)
C0991 LCT ascent motion failure(soft limit error)
C0996 LCT Shift Motor malfunction
C0997 LCT shifting failure
C0998 LCT ejection failure
C099C LCT Shift Gate malfunction
C099D LCT communications error
C0805 Finishing option Paddle Motor malfunction
C0B20 Finishing option Stapler Unit CDdrive failure
C0B2S Finishing option Stapler Unit SlideMotor malfunction
C0830 Finishing option Aligning Bar moving mechanism malfunction
C0B39 Finishing option Front AligningMotor malfunction
C0B3A Finishing option Rear AligningMotor malfunction
C0B48 Finishing option Exit Roller pressure/retraction failure
C0B4A Finishing option Storage Roller pressure/retraction failure
C0B4C Finishing option Exit Motor malfunction
C0B50 Finishing option stapling mechanism malfunction 1
C0B55 Finishing option Staple/Folding Motor malfunction
C0B75 Finishing option Punch Cam Motor drive failure
C0B76 Finishing option Punch Unit Board malfunction
C0B77 Finishing option Punch Side Registration Motor malfunction
C0B78 Finishing option Punch Motor malfunction
C0B79 Finishing option Punch Sensor malfunction
C0B80 Finishing option Shift Motor mechanism malfunction
C0BA0 Finishing option Elevator drive malfunction
C0F30 Abnormally low toner density detected Cyan ATDC Sensor
C0F31 Abnormally high toner density detected Cyan ATDC Sensor
C0F32 Abnormally low toner density detected Magenta ATDC Sensor
C0F33 Abnormally high toner density detected Magenta ATDC Sensor
C0F34 Abnormally low toner density detected Yellow ATDC Sensor
C0F35 Abnormally high toner density detected Yellow ATDC Sensor
C0F36 Abnormally low toner density detected Black ATDC Sensor
C0F37 Abnormally high toner density detected Black ATDC Sensor
C0F3A Cyan ATDC Sensor adjustment failure
C0F3B Magenta ATDC Sensor adjustment failure
C0F3C Yellow ATDC Sensor adjustment failure
C0F3D Black ATDC Sensor adjustment failure
C1200 Standard controller configuration failure
Cl 203 File Memory mounting error
C1204 Memory capacity discrepancy
Cl 220 Image Input Time Out
C1229 Image Output Time Out
C1240 JBIG0 Error
Cl 241 JBIG1 Error
C1242 JBIG2 Error
C1243 JBIG3 Error
C1250 Compressor 0 command buffer stop failure
C1251 Compressor 1 command buffer stop failure
C1252 Compressor 2 command buffer stop failure
C1253 Compressor 3 command buffer stop failure
Cl 261 Compression hardware timeout
C1265 Extraction hardware timeout
C1279 PCI-SDRAM DMA operation failure
C1290 Compression/extraction timeout detection
C12B1 Image processing ASIC failure 1
C12B2 Image processing ASIC failure 2
C12B3 Image processing ASIC failure 3
C12B4 Image processing ASIC failure 4
Cl 2C0 Hard disk recognition error
C12C1 Hard Disk Error 1
C12C2 Hard Disk Error 2
C12C3 Hard Disk Error 3
C12C4 Hard Disk Error 4
C12C5 Hard Disk ErrorS
C12C6 Hard Disk Error 6
C12C7 Hard Disk Error 7
C12C8 Hard Disk Error 8
C12C9 Hard Disk Error 9
C12CA Hard Disk Error A
C12CB Hard disk data transfer error
C12CC Hard disk unformat
C12CF Hard disk specifications error
C12D0 Controller hardware error
C13C8 New Transfer Cleaner Unit reset-ting failure
C13CA New Fusing Unit resetting failure
C13D1 Cyan Imaging Unit EEPROM access error
C1302 Magenta Imaging Unit EEPROM access error
C13D3 Yellow Imaging Unit EEPROM access error
C13D4 Black Imaging Unit EEPROM access error
C13D5 Cyan LPH correction data down-load failure
C13D6 Magenta LPH correction data download failure
C13D7 Yellow LPH correction data download failure
C13D8 Black LPH correction data download failure
C1800 Controller start failure
C3310 CCD clamp/gain adjustment failure
C3331 MSC undefined malfunction occurring
C3332 Scanner Section undefined malfunction
C3333 Engine Section undefined malfunction
C3E00;C3E01;C3E02 NVRAM initialization failure
C3F00 Vendor connection failure
C3FFC ROM contents error upon startup(LPH)
C3FFD ROM contents error upon startup(Scanner)
C3FFE ROM contents error upon startup(PRT)
C3FFF ROM contents error upon startup(MSC)
2helpful
3answers

Biz hub C252

YOU CAN RE-TONE THE MACHINE BY ENTERING SERVICE MODE SELECTING IMAGE PROCESS ADJUSTMENT AND TCR SUPPLY SELECT THE COLOUR THAT IS DEFICIENT AND RUN THE SUPPLY JUST ONCE. BEFORE YOU DO THIS CHECK THAT THE SEALING STRIP ON THE TONERS HAS COME AWAY AND NOT STUCK OVER THE HOLE HENCE STARVING THE MACHINE OF TONER.
4helpful
3answers

Malfunction detected C-0096

C0096 Image Transfer Belt pressure/retraction failure

please have this services as this is a part of the printer that is not consumable.

Code Item
C0000 Main Motor’s failure to turn
C0001 Main Motor turning at abnormal timing
C0016 Bk PC Motor’s failure to turn
C0017 Bk PC Motor’s turning at abnormal timing
C0018 Color PC Drum Motor’s failure to turn
C0019 Color PC Drum Motor’s turning at abnormal timing
C001A Color Developing Motor’s failure to turn
C00l B Color Developing Motor’s turning at abnormal timing
C0040 Suction Fan Motor’s failure to turn
C0046 Fusing Cooling Fan Motor/1 failure to turn
C0048 Fusing Cooling Fan Motor/1 or Fusing Cooling Fan Motor/2 failure to turn
C004C Ozone Ventilation Fan Motor’s failure to turn
C004D Toner Suction Fan Motor’s failure to turn
C004E Power Supply Cooling Fan Motor’s failure to turn
C004F Cooling Fan Motor 2’s failure to turn
C0060 Fusing Drive Motor's failure to turn
C0061 Fusing Drive Motor turning at abnormal timing
C0094 2nd Image Transfer Roller pres-sure/retraction failure
C0096 Image Transfer Belt pressure/retraction failure
C0098 Fusing Pressure Roller pressure/retraction failure
C0200 Cyan PC Drum Charge Corona malfunction
C0202 Magenta PC Drum Charge Corona malfunction
C0204 Yellow PC Drum Charge Corona malfunction
C0206 Black PC Drum Charge Corona malfunction
C0208 PC Drum Charge Corona malfunction
C0400 Exposure Lamp’s failure to turn ON
C0410 Exposure Lamp turning ON at abnormal timing
C0500 Heating Roller warm-up failure
C0501 Fusing Pressure Roller warm-up failure
C0510 Heating Roller abnormally low temperature
C051 1 Fusing Pressure Roller abnormally low temperature
C0520 Heating Roller abnormally high temperature
C0521 Fusing Pressure Roller abnormally high temperature
C0650 Scanner Home Sensor malfunction
C0660 Scanner overrun failure
C0900 Tray3 Elevator failure
C0910 Tray2 Elevator failure
C0950 Tray4 Elevator failure
C0960 Bypass lifting motion failure
C0990 LCT Elevator Motor malfunction(Elevator malfunction)
C0991 LCT ascent motion failure(soft limit error)
C0996 LCT Shift Motor malfunction
C0997 LCT shifting failure
C0998 LCT ejection failure
C099C LCT Shift Gate malfunction
C099D LCT communications error
C0805 Finishing option Paddle Motor malfunction
C0B20 Finishing option Stapler Unit CDdrive failure
C0B2S Finishing option Stapler Unit SlideMotor malfunction
C0830 Finishing option Aligning Bar moving mechanism malfunction
C0B39 Finishing option Front AligningMotor malfunction
C0B3A Finishing option Rear AligningMotor malfunction
C0B48 Finishing option Exit Roller pressure/retraction failure
C0B4A Finishing option Storage Roller pressure/retraction failure
C0B4C Finishing option Exit Motor malfunction
C0B50 Finishing option stapling mechanism malfunction 1
C0B55 Finishing option Staple/Folding Motor malfunction
C0B75 Finishing option Punch Cam Motor drive failure
C0B76 Finishing option Punch Unit Board malfunction
C0B77 Finishing option Punch Side Registration Motor malfunction
C0B78 Finishing option Punch Motor malfunction
C0B79 Finishing option Punch Sensor malfunction
C0B80 Finishing option Shift Motor mechanism malfunction
C0BA0 Finishing option Elevator drive malfunction
C0F30 Abnormally low toner density detected Cyan ATDC Sensor
C0F31 Abnormally high toner density detected Cyan ATDC Sensor
C0F32 Abnormally low toner density detected Magenta ATDC Sensor
C0F33 Abnormally high toner density detected Magenta ATDC Sensor
C0F34 Abnormally low toner density detected Yellow ATDC Sensor
C0F35 Abnormally high toner density detected Yellow ATDC Sensor
C0F36 Abnormally low toner density detected Black ATDC Sensor
C0F37 Abnormally high toner density detected Black ATDC Sensor
C0F3A Cyan ATDC Sensor adjustment failure
C0F3B Magenta ATDC Sensor adjustment failure
C0F3C Yellow ATDC Sensor adjustment failure
C0F3D Black ATDC Sensor adjustment failure
C1200 Standard controller configuration failure
Cl 203 File Memory mounting error
C1204 Memory capacity discrepancy
Cl 220 Image Input Time Out
C1229 Image Output Time Out
C1240 JBIG0 Error
Cl 241 JBIG1 Error
C1242 JBIG2 Error
C1243 JBIG3 Error
C1250 Compressor 0 command buffer stop failure
C1251 Compressor 1 command buffer stop failure
C1252 Compressor 2 command buffer stop failure
C1253 Compressor 3 command buffer stop failure
Cl 261 Compression hardware timeout
C1265 Extraction hardware timeout
C1279 PCI-SDRAM DMA operation failure
C1290 Compression/extraction timeout detection
C12B1 Image processing ASIC failure 1
C12B2 Image processing ASIC failure 2
C12B3 Image processing ASIC failure 3
C12B4 Image processing ASIC failure 4
Cl 2C0 Hard disk recognition error
C12C1 Hard Disk Error 1
C12C2 Hard Disk Error 2
C12C3 Hard Disk Error 3
C12C4 Hard Disk Error 4
C12C5 Hard Disk ErrorS
C12C6 Hard Disk Error 6
C12C7 Hard Disk Error 7
C12C8 Hard Disk Error 8
C12C9 Hard Disk Error 9
C12CA Hard Disk Error A
C12CB Hard disk data transfer error
C12CC Hard disk unformat
C12CF Hard disk specifications error
C12D0 Controller hardware error
C13C8 New Transfer Cleaner Unit reset-ting failure
C13CA New Fusing Unit resetting failure
C13D1 Cyan Imaging Unit EEPROM access error
C1302 Magenta Imaging Unit EEPROM access error
C13D3 Yellow Imaging Unit EEPROM access error
C13D4 Black Imaging Unit EEPROM access error
C13D5 Cyan LPH correction data down-load failure
C13D6 Magenta LPH correction data download failure
C13D7 Yellow LPH correction data download failure
C13D8 Black LPH correction data download failure
C1800 Controller start failure
C3310 CCD clamp/gain adjustment failure
C3331 MSC undefined malfunction occurring
C3332 Scanner Section undefined malfunction
C3333 Engine Section undefined malfunction
C3E00;C3E01;C3E02 NVRAM initialization failure
C3F00 Vendor connection failure
C3FFC ROM contents error upon startup(LPH)
C3FFD ROM contents error upon startup(Scanner)
C3FFE ROM contents error upon startup(PRT)
C3FFF ROM contents error upon startup(MSC)
Not finding what you are looking for?

2,385 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6686 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...