I installed all new imaging unit chip and have gotten the error code c- 2559, installed another new chip and still get code.
Replace the image unit code has nothing to do with the chip!!!
Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f
SOURCE: Reset Chip on Konica Minolta 8031 Imaging Unit
I can provide you with a programmer to reset the chip. They are only about $500-$700. Still interested?
SOURCE: Error code 2557
C-2557 Abnormally low toner density detected black TCR sensor.The TC ratio in the developing machine wich is determined by toner replenishing amount control mechanism is 5% or less for a given number of times consecutively.
Relevant electrical parts:imaging unit K,toner supply motor C/K ,mechanical control board or MFP control board.
Perform image troubleshooting procedure if image density is low.
Clean the TCR sensor window on the underside of the imaging unit if dirty.
Check the toner supply motor operation.
Remove and reinstall imaging unit K. or change the imaging unit.
Last solution turn ON the copier open the front door ,enter in service mode,select sistem1 or 2 ,select IuU Unit,select Unit K ,select new release press start and after job is completed close the front door,turn OFF the power,wait 2 minutes and turn ON.