Honda ev6010 Motor willrun only if kill wire from coil diconnected generator puts out 120 volts

1 Answer

protojexxx

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

  • Expert 61 Answers
  • Posted on Jan 22, 2014
protojexxx
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

Joined: Mar 09, 2010
Answers
61
Questions
0
Helped
20811
Points
115

If you have an ohm letter or continuity tester, put the probes across switch and depress kill while reading meter for a change in resistance. Possible the switch is just bad. If the meter doesn't indicate a change in resistance, switch is definitely bad.

5 Related Answers

protek480

Craig Butler

  • 1730 Answers
  • Posted on Jul 07, 2009

SOURCE: I have a Honda generator model EM3500X with auto

The control board that senses load (current) is not working.It should drop to low with no output current. (nothing running)

If you need further help, I’m available over the phone at https://www.6ya.com/expert/craig_3fa289bf857b1a3c

Ad

Anonymous

  • 1 Answer
  • Posted on Aug 19, 2009

SOURCE: my honda ev6010 engine runs good, but stopped

I am looking for an EV6010 Honda generator. I know they stopped manufacturing them, but I would like to know if anyone has a leftover for sale?
[email protected]

Anonymous

  • 15 Answers
  • Posted on Sep 03, 2009

SOURCE: titan 7000 generator...the generator is not

you know , i have helped several people on thire cars , i want a fix and you want money...not faiir at all....i thought this sight was a helpful sight...i see diferently now....thanks

sal_kh_sab

sal sabea

  • 98 Answers
  • Posted on Oct 20, 2009

SOURCE: No electrical output

probably your AVR card is burnt...
an AVR card is located right outside the stator...looks just like an AK-47 clip (i don't know how else to describe it)...i put a pic below this.
replace it and check again
466fecd.jpgAVR location
168ff0f.jpgAVR card

Sheldon Dedek

  • 912 Answers
  • Posted on Jan 04, 2010

SOURCE: Powermate model 544000 generator undervoltage

There are basically 2 possibilities that can cause this.

1) Enigne RPMs are too low. but, since you already played with the throttle, this probably isn't the case. RPMs should be about 3600 though.

2) The voltage regulator / capacitor has high ESR (resistance) or is bad altogether. Replace.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

U How do you fix a Honda generator 1000i engine runs but no power at 120 out let.

if the motor engine is working and no power output then you need to check is there any power out from the generator motor directly (not in the power out put box I hope you already checked in there) generator motor coils could have busted due to over loads. so even the engine is rotating the generator it can't produce any volts.
0helpful
1answer

Trying to driveRHEEM RAMB-036JAZ using a Honda eu2000 generator. How to hook this up?

You have to very careful powering up home appliances on portable generators due to back feed problems to incoming lines. I would recommend getting an experienced electrician to show and explain the problems with what you are considering. Many linemen have been shocked due to backfeed. The real way to perform this is to get the controller that is put on home generating systems such as generac type systems. These automatically isolate line supply from backup power from home generators, thereby eliminating shock hazards to linemen.
If prolonged shortage, you could disconnect the wires into the furnace and install an extension cord from the furnace to the 120 volt plug on the generator. Most fans are powered on gas furnace on 120 volt. Make sure your voltage needed on your furnace before attempting emergency power up. I have seen some furnaces power by 240 volt fan motors. If it is 240 volt then use the 240 plug wired correctly. PS when you get an electrician to help you with the wiring, check out the requirement to provide grounding, to lessen your shock hazard.
Hope this helps.
1helpful
1answer

Why is my 97 Honda 4 wheeler not getting fire

There are three items that are connected together needed to create spark on your 1997 Honda 4-wheeler, regardless of which model it is.
Before we go through a checklist of these three important parts, look for a black wire with a white stripe that runs to the ignition switch and kill button from the CDI box. Disconnect this wire before it gets to the ignition switch and kill button, then check for spark. The most likely cause is a broken kill switch on the handlebar, or shorted ignition switch. Such a condition grounds this wire and kills the spark.
If this test did not restore the spark, continue reading...
Here is what is required to create a spark.

First, the alternator has one coil which generates a high voltage--about 125 Volts AC for the CDI ignitor box.

Second, there is a pulse voltage generated once every revolution of the engine that goes to the CDI box. This pulse causes the CDI to dump its stored energy from the 125 volt line into the primary of the ignition coil.

Third, If the two connections of the wire that runs from the CDI to the Coil are BOTH SHINY clean, the ignition coil will generate a spark.

If any one of these 3 don't happen, the spark will go away. Of these three, item 3 -- one or two tarnished and/or dirty connectors -- is the most likely cause. Just an added resistance of 0.3 Ohms or more in the CDI to Coil connections will cause the ignition to fail. No other wires have to be this clean.

Sep 26, 2014 • Motorcycles
0helpful
1answer

How do you hook up a headlight on a 6 volt honda odyssey

where are you getting the power feed from?? you are causing a coil ground and killing the power there. do you have a big light that draws to much?? that will also affect the feed to the coil n kill it,a faulty switch or bad wires can ground out
0helpful
1answer

Only has 120 volts,can not get 240volts

the generator consists of 2 120volt windings that run in parallel for 120 volts and in series for 240, check the change over switch make sure a wire hasn't fallen off, if you have a multi meter check both coils have the same resistance
0helpful
1answer

Took my ev6010 generator out and put it back in but hooked up the starter motor to the ground not to the positive and now it wont start. I also changed the oil and coolant.

On the ev6010 Honda generator the posive starter wire is black and was accidently hooked up to the chassis ground wire. Then the start button was pushed and nothing happened. I corrected the wire hookup to the positive side but will not start still
0helpful
1answer

Hi output from generator

I found out that the gasoline motor was turning too fast so I had to turn down the speed of the motor with the adjustment screw.
1helpful
1answer

My honda ev6010 engine runs good, but stopped generating power. I checked the fuses and the 20 amp and the 30 amp breakers. They check good.

I am looking for an EV6010 Honda generator. I know they stopped manufacturing them, but I would like to know if anyone has a leftover for sale?
[email protected]
0helpful
1answer

No 120 or 220 volts out put on portablegenerator motor runs good.

You should find out which wires are you excitation fields and flash them with a 9volt battery. That should make 120 volts
Not finding what you are looking for?

529 views

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...