Often water leaks result in stains on the Stainless Steel, use DeBruce Polish for removal. Using DeBruce Polish on all your stainless steel will allow you to now perform JUST TOUCH UPS of finger printing and remove the need for "OILS" that manufacturers provide for cosmetic care of blending. Stainless IS A GREAT FINISH TO CARE FOR one just needs the right product. Once cleaned with DeBruce Polish there exists no oil or other "films" to BLEND. DeBruce Polish will now perform touch ups instantly. LOVE YOUR STAINLESS STEEL AGAIN! Get DeBruce Polish at debrucepolish.com NON-TOXIC AN ODORLESS ...PERFECT
SOURCE: Water Dispensor leak on Whirlpool Refridgerator
The solenoid valve needs replacing, located at the back of the refrigerator. If you have well water you will need to install a filter on the supply line.
SOURCE: Whirlpool refridgerator-model#ETICHMXKOO4-We have
There is ice buildup in the drain and maybe under the seperator. Remove the back panel in the freezer and the botom floor of the freezer and remove the ice. Be careful of the styrofoam ducts. Eric
SOURCE: ED2KVEXVL Whirlpool refridgerator - not cooling in refridgerator
Tip: Most self-defrosting household refrigerators that loose part or all of their cooling in the freezer or fridge are having problems with the self-defrost system. Three components to check: defrost timer; defrost heater elements (esp. on side x side units); and evaporator fan. All cold air is normally produced in the freezer, then circulated via evaporator fan to the refrigerator section. About every 12 hrs. a defrost timer turns off the compressor, and turns on the defrost elements to melt the frost from the evaporator coils. This normally takes about 20 minutes to complete, then the timer turns off the heaters, and restores normal cooling operations. If the cycle does not complete properly, the coils will "ice up", restricting proper air circulation through the freezer and refrigerator sections. Worse yet is if timer sticks in defrost mode (rare), it will turn the freezer into an oven. If the defrost system seems to be working normally, then you should check the condensing coils for excess dirt, and vacuum &/or bush the dirt and lint out to restore proper head disipation. It's recommended that you vacuum out a condensor that's located on the bottom of the unit once a year. You should also check the condensor fan (if present) for proper operation. If the condensor fan fails, heat can not be properly released from the condensor, and will cause the refrigerator to 'run all the time' yet not cool efficiently. There are many things to check on modern frost-free refrigerators, before turning to the actual sealed refrigeration system and compressor unit.
SOURCE: whirlpool refridgerator is leaking water on the freezer side
WAS IT LEAKING FROM INSIDE THE FREEZER OR FROM BOTTOM OF FRIDGE? ONCE IN A WHILE YOU NEED TO TAKE OUT THE ICE BIN AND DUMP ICE OUT AND CLEAN IT. HOW CAN THE ICE MACHINE OVERFLOW WITH ICE WHEN THE ICE IN THE TRAY WON'T BUDGE? NEED CLARIFICATION. SOUNDS LIKE YOU EITHER HAVE A BAD ICE MAKER MODULE OR THE SOLENOID FOR THE ICE ON THE WATER VALVE IS BAD.