I had a guy come over to fix the little door trigger so the dryer would turn off when you opened the door. About 3 hours after he left, my wife went ot use it and it won't start at all. I checked the outlet, the circuit breaker but got nothing. Is there something he would've done like a manual shut off or reset I need to find?
Do you mean you checked the outlet and breaker and that wasn't the problem, or you have no power there? I can't imagine anything the servicer did that would have required shutting off the power, only to unplug the dryer. The door switch probably isn't working still and the machine won't run because it thinks the door is open. Call the servicer back to check. You should be covered by some kind of warranty for the repair parts and labor.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad. Kenmore Whirlpool Dryer Won Start Easy Fix
Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
Check dryer Terminal block prongs both outside prongs should give combined 220, and 110 each if u check 1 outside & 1 center (ground) prong. Also check house electrical outlet for full voltage.
CHECK THERMAL SHUT OFF THERMOSTAT USUALLY LOCATED ON THE BLOWER. for OHMS or resistance with a meter. Should show a closed circuit. Ohms WHEN THIS FUSE BLOWS IT WILL SHUT DOWN EVERYTHING.
NEXT Test the PUSH start switch with meter for OHMS. Should show OHMS when pushed in or on start, and no ohms or infinity when in off position.
If you hear a humming/clicking sound from motor area you more than likely have a bad motor.
Try this test out to see if u have weak windings or relay/capacitor on motor.
Open the dryer door and turn by hand the drum while machine is on ON position. And you or someone else presses the door engagement switch in. If it starts up then u have bad windings
Another thing to check is the belt safety switch. With a multi meter.
Especially if u just replaced the belt. The belt safety switch is attached to the Tensioner and motor. IT LOOKS LIKE A DOOR SWITCH SOMEWHAT a little black pc of plastic with 2 prongs going into it. Sits at bottom of motor. Under the Tensioner. Attach meter clips to the 2 prongs on switch, Then when the little white push button is pressed in it should show continuity and none when released.
Lastly check ur DOOR SWITCH for continuity with a meter when the button is pushed in the (on/Door closed position,) it may have gone bad.
×