SOURCE: what is wrong with my Maytag refrigerator
You have a bad high voltage board call the manufacturer, if the unit is under 2 yrs old they may help cover the repair with the problem your having.
SOURCE: Maytag refrig (french door) water and ice on door stopped.
1) Electric Water valve check up.
2) Water/Ice dispenser control check up
3) frozen plastic pipe inside door or/and chilled water container frozen
4) old water filter (clogged)
SOURCE: ice buildup in freezer drip pan and water overflow
Your evaporator coils frost up in normal use
and every eight hours or so the entire unit shuts down and the defrost heater
comes on to melt the frost. This cycle last about 20 minutes. The melted frost
drips into a drain pan and through a drain tube to the drain tray under the
freezer/refrigerator where it's evaporated by the condenser fan.
Your drain tube may be stopped up with ice at the upper end
because it drains too slow because it's stopped up at the lower end in the
evaporator pan under the unit at the floor. It can get dust and mold in it.
Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing
it out with hot water and clorox may help.
Make sure it drains quick enough to prevent
refreezing. . The drain should be located below the evaporator coils on the
lower back of the freezer.
SOURCE: Maytag refrigerator is leaking water
Your freezer has a drain that leads to the exterior drain pan beneath the unit. Occasionally this drain can become clogged resulting in standing water inside your freezer,due to line freeze over. This can, also, cause a run-off, as stated in your post. In the freezer, standing water will become ice and may result in defrost problems or inadequate coldness.
You will need to Clear the drain by forcing a solution of water and bleach or water and baking soda into the drain line with a basting syringe. If the solution will not flow through, slide a length of ¼ inch flexible tubing into the drain tube to push the clog through to the drain pan. Remove the tubing after clearing the clog. This will correct the issue.
The drain is located either on the floor of the refrigerator, beneath the vegetable crisper, or in the wall behind a drain funnel.
NOTE_It is important for the refrigerator to be level. If it is not level, doors may not open or close properly and may not seal tightly. Also, drainage from the defrost cycle might be impaired as might the ice making cycle. The appliance was engineered based on it being installed in a level position. While there may be some tolerance for out-of-level installation, the appliance will operate at its best when properly leveled.
Place a level on top of the refrigerator near the front. Do not put it on the door because the door may not be aligned with the refrigerator case. Check that the refrigerator is level from side to side. Next turn the level to check that it is level from front to back.
If it is not level, adjust one or more of the adjustable leveling feet until it is level. The feet are bolts that can be turned to raise or lower the refrigerator. If they cannot be adjusted with your fingers, use a crescent wrench or pliers.
If you have an ice-maker, it should also be checked for level after first leveling the refrigerator. An ice-maker that is out of level will spill water into the ice bin or into the freezer. It can be repositioned by loosening the mounting screws, adjusting it for level and then re-tightening the screws.