Thank you for including model number of product. R8806P101C is 240Volt timer with 4 wiring terminals.
You removed factory wiring and want to reattach. The on-off-auto switch does not have separate wiring diagram. Intermatic offers tech support phone: 815-675-7000
I don't find the Paragon 4004-20 listed in manual. 4004-71 is shown, and uses wiring diagram 3 4004-71B, M, S use wiring diagram 4 4004-06 uses wiring diagram 7 Your timer sounds like a 240V DPST http://waterheatertimer.org/pdf/Paragon-4000-24hr-7000-7day.pdf
Manual shows wiring diagrams, depending on how many screw terminals and loads you have, and voltage of clock motor and voltage of load.
4001-00 is wiring diagram #1 There are 3 terminals 1 2 3 Black Hot wire from circuit breaker goes to terminal 1 Black wire to Load (light, fan, motor) goes to terminal 2 Whites wires connect to terminal 3
×