Heating & Cooling Logo

Related Topics:

Casey Corder Posted on Nov 03, 2013

Samsung mini split air conditioner troubleshooting

How to change remote to read fairenhiet instead of celcius

5 Related Answers

Anonymous

  • 86 Answers
  • Posted on Mar 16, 2008

SOURCE: Westpoint split air conditoner remote contol unit

1.model no.
2.capacity of yr unit.
3 brand name.
mailme [email protected]
i can send to u

Ad

Anonymous

  • 86 Answers
  • Posted on Mar 17, 2008

SOURCE: Supplier of Wireless Remote for Fujitsu Split Air Conditioner

why want to replace remote.no idea abt w.canada

Anonymous

  • 1 Answer
  • Posted on Jun 26, 2010

SOURCE: I have a Chigo Mini Split KF-32GW/A. What is

E5
PG motor
display at
off state
flicker 5/7
SEC
display
at off
state
no feedback
signal of indoor
fan
1、Check whether two sets of plugs on the outlet end of
the motor have loosed from the socket of the
electric control board, insert it firmly when loosing.
2、Check whether the indoor motor has damaged, the
motor should be replaced when it is damaged
3、 Check whether the controllable silicon and other
components on the electric control board have
damaged, replace the controllable silicon or electric
control board when they are damaged.

Anonymous

  • 81 Answers
  • Posted on Jun 28, 2010

SOURCE: Art Cool LA181CNW Split System Air Conditioner: hi, i am using an lg split airconditioner. the sp...

Sound like a defective receiver board. Have this checked. Also check to see that your remote transmits. Hold the top part of the remote to your phone or digital camera lens. press a button and a light should appear on the screen of your phone or digital camera screen.
Hope this helps I take the time to answer your question so please rate me

Anonymous

  • 1 Answer
  • Posted on Sep 28, 2010

SOURCE: I have a bondaire ULB 18HP mini Split Air

I purchased a universal remote CHUNGHOP K-1028E on ebay for this unit but the bad news is it only does basic functions and its in Celius.
Functions that work
On/off
heat
cool
wind/fan speed
mode
Led light
3 flap settings

code is 348 and 453

I also have a harmony one remote and tried learning the original remote functions but doesn't really work properly
GOOD LUCK

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

H4 error code is shown on AC display what can i do to slove this problem

Full list of Gree Air Conditioner Mini Split Units Fault Codes. When error codes appear on the Gree air conditioner indoor display, this tells the user there is an issue with the Gree AC unit. The error code displayed will inform you of the issue or problem that is occurring with the air conditioner. Knowing what the error code means and its definition will help you to understand and troubleshoot the exact Gree air conditioner part that needs to be fixed, cleaned, repaired, or replaced. You can then clean, fix, or replace the Gree part yourself and save money. See below for all error codes that can occur on Gree Mini Split AC's.
Gree Mini Split Air Conditioner Error Codes - How To Fix
Gree Viero AC Mini Split PDF Owners and Troubleshooting Manual
GREE DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

Gree Mini Split Air Conditioner Part Names and Locations
INDOOR AND OUTDOOR UNIT

The Gree Air Conditioning Vireo System has onboard error code diagnostics. The outdoor unit will provide status indicators and the indoor wall unit and remote control will display error codes. The following is a summary of the codes with explanations...
GREE AC DIAGNOSTIC ERROR CODES
Gree Vireo Mini Split Air Conditioner Error Code F0
Refrigerant Leakage Protection
1) Refrigerant leak(s).
2) Indoor coil temperature sensor not calibrated.
3) Refrigerant flow is restricted (ex. valve, exv, debris)
Outdoor Unit Red Light Indicator - 9 flashes and 1 sec Off
Gree Vireo Mini Split Air Conditioner Error Code E1
System High Pressure
1) Over charged with refrigerant.
2) Blocked or dirty outdoor coil.
3) Extreme outdoor ambient conditions
Gree Vireo Mini Split Air Conditioner Error Code E2
Indoor Anti-Freeze Protection
1) Low return airflow.
2) Indoor fan speed is too low.
3) Indoor coil is blocked or dirty.
Outdoor Unit Yellow Light Indicator - 3 flashes and 1 sec Off

Gree Vireo Mini Split Air Conditioner Error Code E4
Compressor High Discharge Temperature Protection
Please refer to the malfunction analysis (discharge temperature, overload) in service manual.
Outdoor Unit Yellow Light Indicator - 7 flashes and 1 sec Off
Gree Vireo Mini Split Air Conditioner Error Code E5
Overcurrent Protection
1) Supply voltage is unstable.
2) Supply voltage is too low and system load is too high.
3) Indoor coil is blocked or dirty.
Outdoor Unit Yellow Light Indicator - 5 flashes and 1 sec Off
Gree Vireo Mini Split Air Conditioner Error Code E6
Communication Malfunction
1) Communication cable is wired incorrectly between indoor and outdoor units.
2) Indoor or Outdoor control board malfunction.
Outdoor Unit Yellow Light Indicator - Continuous On
Gree Vireo Mini Split Air Conditioner Error Code E8
High Temperature Resistant Protection
1) Incorrect refrigerant charge level.
2) Refrigerant metering device malfunction.
3) Compressor malfunction.
Outdoor Unit Yellow Light Indicator - 6 flashes and 1 sec Off
Gree Vireo Mini Split Air Conditioner Error Code EE
EEPROM Memory Malfunction
Control board malfunction.
Outdoor Unit Yellow Light Indicator - 11 flashes and 1 sec Off
Gree Vireo Mini Split Air Conditioner Error Code C5
System Configuration Malfunction
1) No jumper cap inserted on the control board.
2) Incorrect or damaged jumper cap on control board.
3) Indoor and outdoor units are not compatible.
Gree Vireo Mini Split Air Conditioner Error Code Fo
Pump Down or Gathering Refrigerant Status
Optional Service Mode
Outdoor Unit Yellow Light Indicator - 17 flashes and 1 sec Off

NOTE: All of the Gree Air Conditioner Model Numbers below are applicable for the error codes on this page...
Gree AC Vireo Models: VIR09HP115V1A, VIR12HP115V1A, VIR09HP230V1A, VIR12HP230V1A, VIR18HP230V1A, VIR24HP230V1A, VIR30HP230V1A, and VIR36HP230V1A.
Gree Mini Split Air Conditioner Error Code Charts
Gree Mini Split AC Remote Control Button Names
Gree Mini Split AC Remote Control Icons Display Screen

Gree Mini Split Air Conditioner Air Filter Cleaning Procedure
Gree Viero AC Mini Split PDF Owners and Troubleshooting Manual
GREE DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL
Need help with error codes on your Gree AC? Please leave a question below and we will be happy to help.
0helpful
1answer

I have a waves airconditioner. Its not cooling well n after some time show e4 error. How to remove the error? Plz help.

http://acerrorcode.com/tcl-air-conditioner-error-codes.html

This was googled: waves error codes
It showed a page in "images". Stated
"System abnormity" I think. Page was blurry.
Call a tech! Mini splits can be a troubleshooting nightmare! I think its a Fujitsu unit. It would help, and may save you some $$, to call around to find a technician who has worked on mini splits. And maybe find them a 1-800 # that is their tech support # before hand, so if the tech needs it, you have it. E4 is a vague description for a fault. Make sure you have cleaned air filters, cleaned o.d.coil (turn off power at breaker 1st). Changed batteries in remote. Work safe!
12helpful
1answer

I have a goodman mini split.The remote is set to celcius,how do I get it to fahrenheit.model WMH24-1A

To change from Cecilius to Fahrenheit on the remote control, hold both the + and the - simultaneously and this will enable you to toggle between C and F. You will need to do this each time you change your batteries.
0helpful
1answer
0helpful
1answer

Troubleshooting my LG Art Cool Mini split

If the units are close to each other they will both read the same setting. You just have to get the remote really close to the wallmont air handler you want to command.
12helpful
2answers

Samsung AS09XLN air conditioner lights blinking

Sounds like a common problem I have found with Samsung mini split unit. When powering on, does the internal blower attempt to start, then the unit stops and lights blink? If so, on the circuit card there is a 1.2uf or 1.5uf (CBB61) that probably has gone bad. I have replaced several of these. Good luck.
0helpful
1answer

I just installed a ductless mini split 12000. when I put power to it the outside unit compresser runs no fan the led read out just blinks very fast the remote does't do any thing

One thing you need to check is Polarity. the 2 wires red and white, need to be on the same terminals inside as they do outside. this is very important.
0helpful
1answer

Reading the wrong tempeature

Centigrade (celcius) metric temperature .
19C = 66F, 20C = 68F 21C= 70F approx.
25C= 77F, 30C = 86F. There should be a setting to change that to Fahrenheit.
0helpful
1answer

Stand By Mode

1. use remote properly
2.first off the unit then again the unit
3 if same problem change remote by new one
0helpful
1answer

Help with split sysytem

I do not suspect the remote, I think it is the return air sensor on the evaporator coil. If you can remove the plastic cover that encloses the coil do so and vacuum the coil and any sensors you may see. I suspect that a technician will have to perform a resistance test on the sensor.
Not finding what you are looking for?

43 views

Ask a Question

Usually answered in minutes!

Top Samsung Heating & Cooling Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

jws1013

Level 3 Expert

1713 Answers

Are you a Samsung Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...