SOURCE: power up then goes immediately to code sc23-22
Toner pump motor (M28) abnormality. The rotation of the toner pump motor (M28) is checked. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1 second. At this time, error signals (blowout of a fuse and 24V cut off) are not detected.